• C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%

     570,000.00 600,000.00
  • C-TEC Flushing Mount Remote Status Unit Part No. EP210F

          • Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.

          • Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.

          • Three monitored input connections (Hold, Abort and Mode).

          • Max. 8 remote status units per EP203 panel.

          • Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.

     300,000.00 320,000.00
  • C-TEC ActiV Optical Smoke Detector Part No. C4416

        • DESCRIPTION

        • A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.

        • Manufactured by C-TEC in the UK.

        • Third-party certified to EN54-5 by Intertek.

        • Wide 6-33V DC operating voltage.

        • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.

        • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

     28,000.00 30,000.00
  • C-TEC Economy Status Unit Part No. EP211

        • Designed to connect to the EP203 Automatic Extinguisher Panel to provide remote system status indication via three LEDs.

        • Includes a mode (auto/manual) keyswitch.

        • Mounts on a standard UK single gang 25mm flush or surface back box.

        • Max. 8 economy status units per EP203 panel.

     156,000.00 159,000.00

    C-TEC Economy Status Unit Part No. EP211

     156,000.00 159,000.00
  • C-TEC STU Mounting Plate for BF360/12 or BF560/12 12V 2A PSU Part No. BF360SP

    • Facilitates the mounting of a third-party Subscriber Terminal Unit (STU) in a BF360-12 or BF560/12 12V 2A PSU.
    • Finished in 1.2mm steel.
    • Accessory pack includes installation instructions, mounting screws, fixing pads, cable clip and cable tie.
    • Can also be used with a BF360-24 or BF560-24 1.5A 24V PSU by using an ancillary BF360BOX enclosure mounted alongside the PSU.

    Download datasheet

     

  • C-TEC Single Gang Surface Interface Plate, shallow (20mm) Part No. NCP-23

  • C-TEC Single Gang Surface Interface Plate, deep (25mm) Part No. NCP-24

    • Allows standard UK single gang plated products to be fixed to most European style back boxes (square and round variants).
    • Adapts to most European fixing centres – see video for further details.
    • Multiple variants available – options include single gang shallow (NCP23), single gang deep (NCP24), double gang shallow (NCP25) and double gang deep (NCP26).
    • Designed to match C-TEC’s existing plastics and colours.
    • Tough and durable.
    • Can also be surface mounted directly to a wall.
  • C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     295,000.00 300,000.00
  • C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     222,000.00 250,000.00
  • C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.