C-TEC ActiV Optical Smoke Detector Part No. C4416
-
-
-
DESCRIPTION
-
A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.
-
Manufactured by C-TEC in the UK.
-
Third-party certified to EN54-5 by Intertek.
-
Wide 6-33V DC operating voltage.
-
Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
-
Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.
-
-
₦ 28,000.00₦ 30,000.00C-TEC ActiV Optical Smoke Detector Part No. C4416
₦ 28,000.00₦ 30,000.00 -
-
C-TEC Economy Status Unit Part No. EP211
-
-
-
Designed to connect to the EP203 Automatic Extinguisher Panel to provide remote system status indication via three LEDs.
-
Includes a mode (auto/manual) keyswitch.
-
Mounts on a standard UK single gang 25mm flush or surface back box.
-
Max. 8 economy status units per EP203 panel.
-
-
₦ 156,000.00₦ 159,000.00C-TEC Economy Status Unit Part No. EP211
₦ 156,000.00₦ 159,000.00 -
-
C-TEC STU Mounting Plate for BF360/12 or BF560/12 12V 2A PSU Part No. BF360SP
- Facilitates the mounting of a third-party Subscriber Terminal Unit (STU) in a BF360-12 or BF560/12 12V 2A PSU.
- Finished in 1.2mm steel.
- Accessory pack includes installation instructions, mounting screws, fixing pads, cable clip and cable tie.
- Can also be used with a BF360-24 or BF560-24 1.5A 24V PSU by using an ancillary BF360BOXÂ enclosure mounted alongside the PSU.
-
C-TEC Single Gang Surface Interface Plate, shallow (20mm) Part No. NCP-23
-
-
-
- Allows standard UK single gang plated products to be fixed to most European style back boxes (square and round variants).
- Adapts to most European fixing centres – see video for further details.
- Multiple variants available – options include single gang shallow (NCP23), single gang deep (NCP24), double gang shallow (NCP25) and double gang deep (NCP26).
- Designed to match C-TEC’s existing plastics and colours.
- Tough and durable.
- Can also be surface mounted directly to a wall.
-
-
-
-
C-TEC Single Gang Surface Interface Plate, deep (25mm) Part No. NCP-24
- Allows standard UK single gang plated products to be fixed to most European style back boxes (square and round variants).
- Adapts to most European fixing centres – see video for further details.
- Multiple variants available – options include single gang shallow (NCP23), single gang deep (NCP24), double gang shallow (NCP25) and double gang deep (NCP26).
- Designed to match C-TEC’s existing plastics and colours.
- Tough and durable.
- Can also be surface mounted directly to a wall.
-
C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel
-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
₦ 295,000.00₦ 300,000.00C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel
₦ 295,000.00₦ 300,000.00 -
-
C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel
-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
₦ 222,000.00₦ 250,000.00C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel
₦ 222,000.00₦ 250,000.00 -
-
C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel
-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
₦ 195,000.00₦ 200,000.00C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel