• HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel

    • Day/Night Mode Selection.
    • Ground fault detection feature.
    • 24V DC power output for external load.
    • Zone EOL resistor can be set from panel board.
    • Zone Output, Fault Output and Alarm Output (NO. NC. COM).
    • System will back to normal automatically after alarm status is released.
    • Removable front board for easy maintenance.
    • Easy-to-clean front board is able to avoid dirt attached.
    • High luminance and long life span LED.
    • Independent visual & audible indication for zone open/short fault.
    • Independent visual & audible indication for AC power & battery fault.
    • Visual & audible indication for sounder short circuit fault.
    • Buzzer silence with 3-mode operation feature.
    • Accurate supervision circuit for battery.

     

  • HORING LIH AH QP212 2 zone Conventional Fire Alarm Control Panel 

    • Day/Night Mode Selection.
    • Ground fault detection feature.
    • Zone Output, Fault Output and Alarm Output (NO. NC. COM).
    • System will back to normal automatically after alarm status is released.
    • Removable front board for easy maintenance.
    • Easy-to-clean front board is able to avoid dirt attached.
    • High luminance and long life span LED.
    • Independent visual & audible indication for zone open/short fault.
    • Independent visual & audible indication for AC power & battery fault.
    • Visual & audible indication for sounder short circuit fault.
    • Buzzer silence with 3-mode operation feature.
    • Accurate supervision circuit for battery.
  • HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel

    • Removable front board for easy maintenance.
    • Easy-to-clean front board is able to avoid dirt attached.
    • High luminance and long life span LED.
    • Independent visual & audible indication for zone open/short fault.
    • Independent visual & audible indication for AC power & battery fault.
    • Visual & audible indication for sounder short circuit fault.
    • Buzzer silence with 3-mode operation feature.
    • Accurate supervision circuit for battery.
    • Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).
  •  77,000.00 80,000.00

    HORING LIH AH-0014 Flame Detector

     77,000.00 80,000.00
    Buy now
  • C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3

     120,000.00
    Buy now
  • C-TEC Single Gang Locking Jack Socket for BF320 Part No. BF320JP

  • C-TEC Remote LED Indicator Part No. BF318

  • C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM

    • A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
    • Up to 30 BF365IM modules per BF365SC controller.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
  • C-TEC CFP 8 Zone Repeater Panel Part No. CFP760

      • Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).

      • Up to 8 repeaters per CFP master.

      • Includes its own Mains power supply that requires its own standby battery supply.

      • Provides the user with access to all AL1 and AL2 functions.

      • Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).

      • Communicates over screened two-wire fire resistant cable.

      • Total repeater network cable length should not exceed 1KM.

      • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

     295,000.00 300,000.00

    C-TEC CFP 8 Zone Repeater Panel Part No. CFP760

     295,000.00 300,000.00
    Buy now
  • C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%