Addressable Interface/Module Device implements communication between fire control panels and a personal computer. Also between fire control panels in a network. In Fire Control Panels, the module is fitted.
Compatible with all intelligent control panels currently in use. Installed on a normal 35mm DIN rail or in a stand-alone enclosure. Short-circuit isolation maintains loop continuity in the event of device failure, and a tri-color LED displays local status.
Generally interface units come in 3 forms for use with addressable fire alarm systems:
- Input unit
- The output unit (either monitored or unmonitored for faults)
- Input/output unit.
Replacing and upgrading existing conventional systems with a new addressable system in stages. In physically well-defined places such as distinct machinery rooms and boiler buildings, the module allows the use of lower-cost traditional detectors.
-
Addressable input interface unit
-
Complies with EN54 Part18
-
Low profile
-
DIN rail mounted
-
Accepts normally open input circuits
-
Monitors input circuit wiring for open or short circuit faults
-
Gent Interface S4-3440-02 Panel
🔧 Key Features:
-
Versatile I/O Configuration: Supports multiple input and output connections for flexible system integration.
-
Seamless System Expansion: Ideal for interfacing fire panels with BMS, security, or access control systems.
-
LED Indicators: Provides real-time status feedback for easier monitoring and maintenance.
-
Robust & Compact Design: Engineered for durability with easy installation in a wide range of environments.
-
Compatible with Gent Vigilon Systems: Fully integrated within the Gent ecosystem for reliable performance.
✅ Applications:
-
High-rise buildings
-
Hospitals and healthcare facilities
-
Commercial offices
-
Manufacturing and industrial plants
-
Education and government infrastructure
₦ 1,890,000.00₦ 1,900,000.00Buy nowGent Interface S4-3440-02 Panel
₦ 1,890,000.00₦ 1,900,000.00 -
-
Gent VSRPT-MRC-72 Replacement MRC for New Repeat, A3 & A2 Mimic (BS & EN)
Gent VSRPT-MRC-72 Replacement MRC for New Repeat, A3 & A2 Mimic (BS & EN)
The replacement Master Repeat Card (MRC) Mark-4 (VSRPT-MRC-72 or CP4S-RPT-MRC-XXX) is designed for installation into a new Repeat panel or A3 Mimic panel, that are wired on to a loop of an EN54 or BS5839 analogue and addressable fire detection and alarm systems.
₦ 1,200,000.00Buy now -
Gent VSRPT-IDOOR-PLUS Vigilon EN54 Repeat Panel Inner Door Assembly
Gent VSRPT-IDOOR-PLUS Vigilon EN54 Repeat Panel Inner Door Assembly (Black)
The VSRPT-IDOOR-PLUS is a Vigilon EN54 Repeat Panel Inner Door Assembly.
₦ 1,285,000.00₦ 1,500,000.00Buy nowGent VSRPT-IDOOR-PLUS Vigilon EN54 Repeat Panel Inner Door Assembly
₦ 1,285,000.00₦ 1,500,000.00 -
Gent S4-34410 Single Channel Interface LV Input
Gent S4-34410 Single Channel Interface LV Input
Interfaces are used to link the fire alarm system to other plant management devices such as sprinklers and security systems. They can also be used to link to a zone of conventional detectors. The Vigilon system can accommodate a high capacity of single channel interfaces on the loop operating both inputs and outputs.
₦ 67,500.00₦ 70,000.00Buy nowGent S4-34410 Single Channel Interface LV Input
₦ 67,500.00₦ 70,000.00 -
Gent VSINTL-PCB Replacement Card for Loop Powered Interface (34450)
Gent VSINTL-PCB Replacement Card for Loop Powered Interface (34450)
The VSINTL-PCBÂ from Gent is a Replacement Card for Loop Powered Interface (34450).
-
Gent VSINT-KEY Spare Key Pack for 34450 & 34440 (2 Keys)
Gent VSINT-KEY Spare Key Pack for 34450 & 34440 (2 Keys)
The VSINT-KEY is a Spare Key Pack for 34450 & 34440 (2 keys).
₦ 50,000.00Buy now -
Gent VS-PSU-RPL Backwards Compatible PSU for Old Style Vigilon Panels
Gent VS-PSU-RPL Backwards Compatible PSU for Old Style Vigilon Panels
The Gent VS-PSU-RPL is a backwards compatible PSU which is used for the old style vigilon panels.
-
Gent VS-KEY Vigilon Outer Door Key
Vigilon Outer Door Key
The Gent Vigilon  is Vigilon Outer Door Key an ideal replacement and spare access key for the Gent Vigilon and Vigilon Compact Panel Outer Door.
-
Gent VS-BATTBOX Battery Box for Vigilon Panel (Excludes Batteries)
Gent VS-BATTBOXÂ Battery Box for Vigilon Panel (Excludes Batteries)
The VS-BATTBOX is a Battery Box for Vigilon Panel (excludes batteries).
₦ 2,700,000.00Buy now -
Gent VIG-MCC-EN Vigilon Main Control Card EN54 Zonal Display
Gent VIG-MCC-EN Vigilon Main Control Card EN54 Zonal Display
The Gent VIG-MCC-EN is a replacement main control card EN54 zonal display for use with the Gent Vigilon panel.
₦ 651,000.00₦ 690,000.00Buy nowGent VIG-MCC-EN Vigilon Main Control Card EN54 Zonal Display
₦ 651,000.00₦ 690,000.00 -
Gent S4-34440-02 Mains Powered Interface c/w batteries (Output rated 1.5A) 24V battery AUX Supply
The S4-34440-02 module has been designed to be installed in custom panel to provide supervisory input to control plant via Vigilon System. The module connects to a loop circuit of a Vigilon fire alarm control panel.
₦ 428,000.00₦ 455,000.00Buy nowGent S4-34440-02 Mains Powered Interface c/w batteries (Output rated 1.5A) 24V battery AUX Supply
₦ 428,000.00₦ 455,000.00 -
Gent 19104-52 Din Rail Mounting Polarised Relay for Mounting Inside the Interface
Gent 19104-52 Din Rail Mounting Polarised Relay for Mounting Inside the Interface
The 19104-52 is a DIN rail mounting polarised relay designed for use with the S4-34440-02 and S4-34440-12 interface units.
₦ 120,000.00Buy now