Welcome to Top Store

Cart

Your Cart is Empty

Back To Shop

Category: Aspirating Detection System

Aspirating detection system; an active fire protection system. Consists of a central detection unit that detects the smoke by drawing air via a network of pipes. A nephelometer detects the presence of smoke particles floating in the air by detecting the light dispersed by them in the chamber. Smoke detected by aspirating detecting devices being apparent to the human eye. Requires a fan unit to extract a sample of air from the protected area through a network of pipes.

Fully integrated with traditional fire detection systems and aesthetics modified to be sympathetic to the environment. They are installed, making them ideal for high-risk, high-value environments such as data centers/server rooms and distribution centers. Early detection systems come in a variety of configurations to suit a wide range of situations and applications.

Corrects shortcomings of conventional smoke detectors by using a sampling pipe with multiple holes.

Showing all 10 results

  • FAAST ASD Interface

    Description The ASD Interface is designed to integrate FAAST aspirating detection onto the Vigilon loop via a combined Power Supply Unit (PSU) and loop interface. The PSU provides necessary power and 24 hour battery backup compliant to EN54-4. The ASD Interface is supplied in a bundle kit complete with a FAAST or FAAST LT as …

    FAAST ASD InterfaceRead More

    Read more
  • Gent by Honeywell Vesda-E VEA-40 Aspirating Smoke Detector with 3.5” TouchScreen Display(VEA-040-A10)

    Vesda-E VEA-40 Aspirating Smoke Detector
    combines VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.They use patented air sampling points and multichannel microbore air-sampling with three alarm sensitivity settings for the sampling points. As a
    multi-channel, addressable system, the VEA detector is able to divide a
    protected space into sampling locations, enabling the localization of potential sources of fire for faster incident response. The detectors are suitable for
    protection of areas where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for healthcare, offices, education, retail, prisons and electrical cabinets. A wide range of features provide flexibility, field programmability, enhanced connectivity and reduced total cost of ownership.

    Read more
  • Gent by Honeywell VESDA-E VEA-40 Aspirating Smoke Detector with LED Displays(VEA-040-A00)

    combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.
    They use patented air sampling points and multichannel microbore air-sampling with three alarm sensitivity settings for the sampling points. As a
    multi-channel, addressable system, the VEA detector is able to divide a
    protected space into sampling locations, enabling the localization of potential sources of fire for faster incident response. The detectors are suitable for
    protection of areas where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for healthcare, offices, education, retail, prisons and electrical cabinets. A wide range of features provide flexibility, field programmability, enhanced connectivity and reduced total cost of ownership.

    Read more
  • Gent by Honeywell VESDA-E VEA(VER-A40-40-STX)

    DESCRIPTION

    The VESDA-E VEA series of detectors
    combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.COLOUR LCD DISPLAY
    The VEA-040-A10 detector features a 3.5” colour LCD display which provides a range of status information including alarm and fault conditions as well as smoke level. Screens for each type of information are available using a simple navigation system.
    VESDAnet™
    VESDA detectors and devices communicate on VESDAnet which provides a
    robust bi-directional communication network allowing continued redundant operation even during single point wiring failures. VESDAnet enables primary reporting, centralized configuration, control, maintenance and monitoring.
    ETHERNET AND WIFI CONNECTIVITY
    VESDA-E detectors offer Ethernet and WiFi connectivity as standard features. The detector can be added to a corporate network, allowing WiFi enabled tablet devices and laptops installed with Xtralis configuration software to connect
    wirelessly to the detector via the network.
    The VESDA-E VEA series of detectors
    combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors

    Read more
  • GENT INTERFACE ENCLOSURE LARGE PLASTIC(S4-34490)

    75,000.00

    Gent Interface Enclosure Large Plastic (S4-34490) is designed to house Gent S4 loop-powered interfaces.

    Add to cart
  • GENT INTERFACE ENCLOSURE SMALL PLASTIC SURFACE MOUNT BOX (M200E-SMB)

    Description

    GENT INTERFACE ENCLOSURE SMALL PLASTIC SURFACE MOUNT BOX (M200E-SMB) is a housing for Vigion’s loop powered interfaces. Vigilon’s range of loop powered interfaces offer a comprehensive range of connectivity options with critical plant and other safety systems. Vigilon can accommodate a high quantity of loop powered interface units offering fexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fi re, to linking with other emergency management systems such as sprinklers or security systems. Loop powered interfaces offer a cost effective solution with each device individually addressed increasing the overal management capability of the FD&A system.
    Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.

    Read more
  • Gent Loop Powered Interfaces- Single Input(S4-34410)

    Vigilon’s range of loop powered interfaces offer
    a comprehensive range of connectivity options
    with critical plant and other safety systems.
    Vigilon can accommodate a high quantity of loop powered interface units
    offering fexible range of inputs and outputs from the FD&A system from
    plant control and signalling other systems in a fi re, to linking with other
    emergency management systems such as sprinklers or security systems.

    Read more
  • Gent Loop Powered Interfaces-Single Input/Output(S4-34420-02)

    400,000.00

    Description Gent Loop Powered Interfaces Gent Loop Powered Interfaces are used to link the fire alarm system to other plant management devices such as sprinklers and security systems. They can also be used to link to a zone of conventional detectors. The Vigilon system can accommodate a high capacity of single channel interfaces on the …

    Gent Loop Powered Interfaces-Single Input/Output(S4-34420-02)Read More

    Add to cart
  • Gent Loop Powered Interfaces(VSINTM-PCB-UPG)

    Vigilon’s range of loop powered interfaces offer
    a comprehensive range of connectivity options
    with critical plant and other safety systems.
    Vigilon can accommodate a high quantity of loop powered interface units
    offering fexible range of inputs and outputs from the FD&A system from
    plant control and signalling other systems in a fi re, to linking with other
    emergency management systems such as sprinklers or security systems.
    Loop powered interfaces offer a cost effective solution with each device
    individually addressed increasing the overal management capability of the
    FD&A system.
    Interfaces are either powered from the loop or require a separate mains
    supply. The mains power version has its own battery backup.

    Read more
  • Gent Single Channel Interfaces – Input/Otput(S4-34420)

    47,000.00

    Description
    Vigilon’s range of loop powered interfaces offer
    a comprehensive range of connectivity options
    with critical plant and other safety systems

    Vigilon can accommodate a high quantity of loop powered interface units
    offering fexible range of inputs and outputs from the FD&A system from
    plant control and signalling other systems in a fi re, to linking with other
    emergency management systems such as sprinklers or security systems.

    Add to cart

Cart

Your Cart is Empty

Back To Shop