Control panels connect detectors, alarms, suppression systems, and monitoring stations to communicate fire detection and response signals.
Control panel activate visual, audio, and occasionally other forms of notification equipment to alert residents of an emergency situation.
There are two kinds of fire panels available today: Addressable fire alarm panel vs. conventional fire alarm panel. A conventional fire alarm control panel employs one or more circuits, connected to initiating devices wired in parallel. Addressable panels are more advanced than traditional panels, with greater information capacity and control flexibility.
Voice evacuation panels are another type of fire alarm control panel. Designed to provide outputs for speakers in the system.
A fire suppression system will be installed on important and valuable structures. The panel notifies a monitoring center of the alarm status, and people at the receiving location decide what to do next. The panel controls HVAC systems, building automation controls, access points, and elevators to isolate the fire or route workers.
-
GENT 8 ZONE REPEAT INDICATOR, LESS BATTERIES (13271-08LB)
Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 (Less Batteries)
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
Utilising LPCB approved conventional smoke or heat detectors, Xenex offers exceptional value for money.
₦ 255,000.00₦ 265,000.00GENT 8 ZONE REPEAT INDICATOR, LESS BATTERIES (13271-08LB)
₦ 255,000.00₦ 265,000.00 -
Zeta Infinity 8 Conventional 4 Zone-Fire-Alarm-Panel IN4
✅ Key Advantages:
-
🚨 4-Zone Fire Monitoring: Effectively covers up to four separate detection areas for enhanced protection.
-
🔄 User-Friendly Interface: Simple, intuitive controls make operation and maintenance hassle-free.
-
⚡ High Reliability: Advanced detection algorithms reduce false alarms and increase system accuracy.
-
🔒 Built-in Safety Features: Includes fault monitoring and alert system to ensure constant readiness.
-
🔧 Flexible Integration: Compatible with a wide range of conventional fire detection devices.
-
🛠️ Easy Installation: Compact design and clear labeling for quick setup by professionals.
Whether for offices, schools, shops, or small complexes, the Zeta Infinity 8 is your smart choice for dependable fire safety.
📦 Available now at Trends Ventures Limited
₦ 427,350.00₦ 430,000.00Zeta Infinity 8 Conventional 4 Zone-Fire-Alarm-Panel IN4
₦ 427,350.00₦ 430,000.00 -
-
Gent 4 ZONE CONVENTIONAL PANEL
DESCRIPTION
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
₦ 708,750.00₦ 720,000.00Gent 4 ZONE CONVENTIONAL PANEL
₦ 708,750.00₦ 720,000.00 -
Zeta Infinity 8 Conventional 2 Zone Fire Alarm Panel IN2
🔒 Advantages:
-
✅ Supports up to 2 detection zones – ideal for compartmentalized monitoring
-
✅ LED indicators for instant status updates
-
✅ Easy installation and intuitive user interface
-
✅ Compatible with a wide range of conventional detectors and devices
-
✅ Built-in fault monitoring and zone isolation functions
-
✅ Compact, sleek design fits any control room or wall space
-
✅ Manufactured by Zeta Alarm Systems – trusted worldwide
Perfect for schools, small offices, retail spaces, and more.
🛒 Get protected today — choose smart, choose Zeta Infinity 8.
₦ 362,775.00₦ 370,000.00Zeta Infinity 8 Conventional 2 Zone Fire Alarm Panel IN2
₦ 362,775.00₦ 370,000.00 -
-
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).
-
C-TEC CFP 8 Zone Repeater Panel Part No. CFP760
-
-
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
-
Up to 8 repeaters per CFP master.
-
Includes its own Mains power supply that requires its own standby battery supply.
-
Provides the user with access to all AL1 and AL2 functions.
-
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
-
Communicates over screened two-wire fire resistant cable.
-
Total repeater network cable length should not exceed 1KM.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
₦ 295,000.00₦ 300,000.00C-TEC CFP 8 Zone Repeater Panel Part No. CFP760
₦ 295,000.00₦ 300,000.00 -
-
C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
-
Technical Specifications
-
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
-
Mains supply 230V 50/60Hz.
-
Mains rated current 810mA max.
-
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
-
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
-
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
-
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
-
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
-
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
-
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
-
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
-
Max. sounder output current 3 x 200mA.
-
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
₦ 570,000.00₦ 600,000.00C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
₦ 570,000.00₦ 600,000.00 -
-
C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel
-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
₦ 295,000.00₦ 300,000.00C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel
₦ 295,000.00₦ 300,000.00 -
-
C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel
-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
₦ 222,000.00₦ 250,000.00C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel
₦ 222,000.00₦ 250,000.00 -