Control panels connect detectors, alarms, suppression systems, and monitoring stations to communicate fire detection and response signals.
Control panel activate visual, audio, and occasionally other forms of notification equipment to alert residents of an emergency situation.
There are two kinds of fire panels available today: Addressable fire alarm panel vs. conventional fire alarm panel. A conventional fire alarm control panel employs one or more circuits, connected to initiating devices wired in parallel. Addressable panels are more advanced than traditional panels, with greater information capacity and control flexibility.
Voice evacuation panels are another type of fire alarm control panel. Designed to provide outputs for speakers in the system.
A fire suppression system will be installed on important and valuable structures. The panel notifies a monitoring center of the alarm status, and people at the receiving location decide what to do next. The panel controls HVAC systems, building automation controls, access points, and elevators to isolate the fire or route workers.
-
🛑Orisong/Concept Plus Smoke Detector
✅ Rapid Smoke Detection
✅ Low Power Consumption
✅ Durable and Easy Maintenance
✅ Ideal for Residential & Commercial Use🛒 Available now at Trends Ventures Ltd
₦ 6,825.00₦ 6,925.00🛑Orisong/Concept Plus Smoke Detector
₦ 6,825.00₦ 6,925.00 -
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).