Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
- You cannot add that amount of "C-TEC CFP Network Card - fire alarm panels" to the cart because there is not enough stock (0 remaining).
-
Zeta ID2/4/M Infinity ID2 Intelligent 2 Wire 4 Zone Fire Panel in Metal Enclosure
Description
Zeta Alarm Systems is proud to introduce the most
advanced
2 wire system on the market. We can now
provide
a system that gives all of the benefits associated
with
a ‘2 Wire’ installation (less cable, quicker installation,
cost savings on labour/product) and has the facility to
‘I.D.’ the devices.
The system is built on the proven communication protocol
developed by Zeta Alarm Systems and shares the same
platform as our largest, most powerful system.
The ID2 can be used for new installations, as
a retrofit for any conventional system or as a replacement for
existing
2 wire systems when the extra features are
deemed to be desirable/necessary. This is possible
because the ID2 devices sit on radial circuits, thus
making it easy to ‘upgrade’
a system with the facility to
I.D. devices without the need to re-wire.
Technical -
Zeta ID2/8/M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure
DESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
-
Zeta ID2/REP/M Infinity ID2 Intelligent 2 Wire Full Function Repeater in Metal Enclosure
DESCRIPTION
The Infinity ID2 active repeater is used on an Infinity ID2 Panel.
It is powered from the ID2 Panel, so is connected via 4 cores: 2 x power and 2 x data. Op to 8 repeaters can be connected. The first 2 repeaters can be powered from the panel. Subsequent repeaters would need an external power supply.
Each repeater can be selectively configured to determine which commands it will send to the network. EG to allow some repeaters to reset the system, and others to not reset the system.
Each Repeater can also be configured to run in a different language (Although any device labels entered by the installer will just be in the language entered) -
Gent MAINS POWERED DUA Â 60 Watt Mains Powered Distributed Amplifier (COMPACT-MAINS-DAU)
The Gent MAINS POWERED DUA is a new addition to Compact Voice increasing the design capability and flexibility of the system. The new Amplifier Unit allows connection to a comprehensive range of standard 100 volt loudspeakers meeting the needs of any VA application at the same time as maintaining the advantages already delivered by the Compact Voice system. The new Amplifier Unit allows connection to a comprehensive range of standard 100 volt loudspeakers meeting the needs of any VA application at the same time as maintaining the advantages already delivered by the Compact Voice System.
-
Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds (VIG-BNG-RW)
Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds
The BACnet protocol is a Standard (Ansi/Ashrae 135-2004). With the Gent BACnet Gateway Assembly, devices on Vigilon fire alarm control panels are represented as BACnet objects to the BACnet client. The user subscribes to Event Notification objects from the FACP as required and the BACnet device receives events from objects on the FACP as a result of the subscription.
₦ 825,000.00Buy nowGent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds (VIG-BNG-RW)
₦ 825,000.00 -
Gent 2.8M Venturi Tube for Duct Housing (S4-34760-28)
The S4-34760-28 from Gent is a 2.8 Venturi Tube for use with Duct Smoke Sensors. This device shall employ a molded plastic housing with a clear viewing window and metal probes (Gent 2.8M Venturi Tube) to pick up smoke in ventilation ducts. The housing shall provide a smoke entry test point and an airflow indication. Depending on the risk and sensitivity levels required, the sensor to be fitted shall be selected from the full range of sensors available and not factory fitted. This unit is particularly suitable for sensing smoke particles in ducting which is likely to be in large quantity and flowing fairly quickly.
-
Gent Duct Smoke-Sensor Housing (S4-34760 )
Gent Duct Smoke-Sensor Housing – S4-34760 is specifically designed for use in ventilation ducting. It is mounted externally to the duct, the device uses venturi probe technology to sample the air for smoke. If smoke is detected, the device triggers the shut down of air-conditioning or ventilation systems to isolate the hazard and prevent it from spreading.
₦ 295,000.00Buy nowGent Duct Smoke-Sensor Housing (S4-34760 )
₦ 295,000.00 -
Gent Dual Optical Heat&CO Sensor (S4-901)
Gent S4-901 CO Dual Optical Heat Sensor
A new concept in fire detection – a truly intelligent analogue sensor combining exceptional computing power in the sensor as well as the panel to achieve an extremely fast response to a real fire whilst minimising the risk of false alarms.
₦ 75,000.00Buy nowGent Dual Optical Heat&CO Sensor (S4-901)
₦ 75,000.00 -
Honeywell Gent 240V Electronic Bell 155 x 85m
✅ Key Advantages:
-
High Audibility: Produces a loud, clear ring that’s impossible to ignore.
-
Durable Design: Built to withstand demanding environments with consistent performance.
-
Quick Activation: Instant sound response for fire alarms and emergency notifications.
-
Low Maintenance: Reliable electronic mechanism requires minimal upkeep.
-
Trusted Brand: Manufactured by Honeywell Gent, a global leader in life safety technology.
₦ 15,750.00₦ 16,000.00Buy nowHoneywell Gent 240V Electronic Bell 155 x 85m
₦ 15,750.00₦ 16,000.00 -
-
Gent 74430-88NM 6 inch Fire Red Ball Sounder 24v Dc
- Designed with a modern feel
- Has a loud ring output
- There’s an option of a weatherproof kit
- All parts clip together to assemble
₦ 67,000.00Buy now -
Honeywell Notifier 74432-88NM Conventional Red Fire Bell 24 VDC
- Designed with a modern feel
- Has a loud ring output
- There’s an option of a weatherproof kit
- All parts clip together to assemble