Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.

Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.

Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.

  • C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3

     120,000.00
    Buy now
  • C-TEC Single Gang Locking Jack Socket for BF320 Part No. BF320JP

  • C-TEC Remote LED Indicator Part No. BF318

  • C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM

    • A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
    • Up to 30 BF365IM modules per BF365SC controller.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
  • C-TEC CFP 8 Zone Repeater Panel Part No. CFP760

      • Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).

      • Up to 8 repeaters per CFP master.

      • Includes its own Mains power supply that requires its own standby battery supply.

      • Provides the user with access to all AL1 and AL2 functions.

      • Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).

      • Communicates over screened two-wire fire resistant cable.

      • Total repeater network cable length should not exceed 1KM.

      • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

     295,000.00 300,000.00

    C-TEC CFP 8 Zone Repeater Panel Part No. CFP760

     295,000.00 300,000.00
    Buy now
  • C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%

     570,000.00 600,000.00
    Buy now
  • Fire Alarm Control Panel Mains Keyswitch Part No. BF319

    • A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
    • Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
    • Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
    • Fits on a standard UK 47mm flush or surface mount back box.
    • Supplied with 2 x M3.5 25mm fixing screws.
    • BS EN60669-1 compliant.
    • Always read the full installation and operating instructions supplied with the unit before use.
  • C-TEC Remote Status Unit, Surface Part No. EP210S

          • DESCRIPTION
          • Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
          • Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
          • Three monitored input connections (Hold, Abort and Mode).
          • Max. 8 remote status units per EP203 panel.
          • Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
  • C-TEC System Line Terminator Part No. EP214

          • An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
          • Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
          • One EP214 terminator is required per solenoid.
          • Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
          • Measures just 55m W x 55mm H x 22mm D.
  • C-TEC Flushing Mount Remote Status Unit Part No. EP210F

          • Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.

          • Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.

          • Three monitored input connections (Hold, Abort and Mode).

          • Max. 8 remote status units per EP203 panel.

          • Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.

     300,000.00 320,000.00
    Buy now
  • C-TEC Output Expansion Relay Board Part No. EP212

      • An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
      • Mounts inside the EP203 panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
      • Reset relay switches during the panel’s reset cycle.
      • Mode relay switches when the extinguishant system’s mode is changed to manual.
      • Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
      • Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
      • Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
  • C-TEC ActiV Optical Smoke Detector Part No. C4416

        • DESCRIPTION

        • A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.

        • Manufactured by C-TEC in the UK.

        • Third-party certified to EN54-5 by Intertek.

        • Wide 6-33V DC operating voltage.

        • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.

        • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

     28,000.00 30,000.00
    Buy now