A fire alarm system notifies us of an emergency, to take action to protect ourselves, our employees, and the general public.
Fire detection systems identify fire early when there is still enough time for inhabitants to safely evacuate. Control actions begin while the fire is still minor, early detection helps to reduce property loss and operational disruption. Fire alarm systems transmit information about the location of the fire to emergency responders, speeding up the firefighting procedure.
Sounders go off to warn those within the building that there may be a fire. The fire alarm system could include a remote signal system. It would then notify the fire department via a central station.
- You cannot add that amount of "Beam Sensor 250m – Advanced Perimeter Protection" to the cart because there is not enough stock (0 remaining).
-
Zeta MKII-AXTB/R Addressable Fyreye Xtratone Red Sounder Beacon
Key Features:
-
101dB @ 1m sound output
-
16 tones can be selected from control panel
-
White Flash rates between 0.33Hz and 1.5Hz
-
Hard addressed via 8 way dip-switch
-
Can also be soft addressed via MKII Handheld Programmer
-
Flush or surface fixing
-
Housed in UL V0 flame retardant ABS
-
4 x 20mm cable entries (2 top, 2 bottom)
-
First fix, wire to back box technology
₦ 129,150.00₦ 130,000.00Zeta MKII-AXTB/R Addressable Fyreye Xtratone Red Sounder Beacon
₦ 129,150.00₦ 130,000.00 -
-
CTEC CFP Conventional Power Supply Unit – fire alarm systems
✅ Key Features:
-
Stable 24V DC regulated output
-
Built-in fault monitoring
-
Battery backup support
-
LED status indicators
-
Easy wall mounting design
Whether for commercial or residential use, the CTEC CFP Power Supply guarantees your fire protection systems remain operational when it matters most.
₦ 125,475.00₦ 131,450.00CTEC CFP Conventional Power Supply Unit – fire alarm systems
₦ 125,475.00₦ 131,450.00 -
-
Zeta Conventional Yellow BreakGlass Weatherproof Call Point (Fire Alarm System)
Key Features:
-
Bright yellow finish for gas release alert
-
IP-rated weatherproof casing for outdoor use
-
Durable construction for high-impact resistance
-
Clear glass panel for instant manual activation
-
Compliant with global fire safety standards
₦ 122,850.00₦ 128,700.00Zeta Conventional Yellow BreakGlass Weatherproof Call Point (Fire Alarm System)
₦ 122,850.00₦ 128,700.00 -
-
Zeta Conventional Blue Breaklglass Weatherproof (Fire Alarm System)
Key Features:
-
Weatherproof IP-rated enclosure for outdoor and industrial use
-
High-visibility blue casing for fast identification
-
Break glass design for quick activation
-
Durable construction to withstand tough environments
-
Compatible with Zeta and other conventional safety systems
₦ 122,850.00₦ 128,700.00Zeta Conventional Blue Breaklglass Weatherproof (Fire Alarm System)
₦ 122,850.00₦ 128,700.00 -
-
🔥Orisong / Concept Plus 2-Zone Fire Alarm Panel 🔥
✅ Fast fire detection
✅ Easy installation & user-friendly interface
✅ Supports multiple detectors and sounders
✅ Durable, compact design for optimal performanceDon’t wait until it’s too late — ensure maximum protection and peace of mind today!
₦ 121,275.00₦ 131,275.00🔥Orisong / Concept Plus 2-Zone Fire Alarm Panel 🔥
₦ 121,275.00₦ 131,275.00 -
CTEC Deep Base Addressable Sounder (Outdoor) – fire alarm
✅ Key Features:
-
Addressable integration with fire alarm panels
-
High-volume sound output for outdoor audibility
-
Weatherproof deep base for enhanced durability
-
Easy to install and maintain
-
Low power consumption with reliable performance
🛒 Perfect for: Outdoor security systems, fire alarm installations, emergency warning setups.
₦ 120,750.00₦ 126,500.00CTEC Deep Base Addressable Sounder (Outdoor) – fire alarm
₦ 120,750.00₦ 126,500.00 -
-
₦ 120,000.00
₦ 125,000.00C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 120,000.00₦ 125,000.00 -
C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3
-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Eight conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
₦ 120,000.00 -
-
Beam Sensor 250m – Advanced Perimeter Protection
✅ Functions & Features:
-
📡 250m Detection Range: Perfect for outdoor perimeter security.
-
🌧️ Weatherproof Design: Built to withstand rain, dust, and harsh conditions.
-
🔊 Instant Alarm Triggering: Sends immediate alerts when the beam is interrupted.
-
🔄 Adjustable Beam Alignment: Ensures precise coverage and reduced false alarms.
-
⚡ Low Power Consumption: Energy-efficient with high performance.
-
🛠️ Easy Installation: Compatible with most alarm systems and CCTV setups.
Ideal for homes, schools, offices, banks, warehouses, estates, and restricted zones.
₦ 115,500.00₦ 117,500.00Beam Sensor 250m – Advanced Perimeter Protection
₦ 115,500.00₦ 117,500.00 -
-
C-TEC CFP Network Card – fire alarm panels
✅ Enables networking of up to 8 CFP panels
✅ Supports Class Change & Fault Monitoring
✅ Plug-and-play compatibility
✅ Reliable & robust communication interface
✅ Designed for ease of installation & maintenancePerfect for schools, offices, industrial complexes, and commercial buildings looking to scale their fire alarm systems efficiently.
₦ 114,975.00₦ 120,450.00C-TEC CFP Network Card – fire alarm panels
₦ 114,975.00₦ 120,450.00 -
C-TEC Open-Area Addressable Indoor Sounder – fire alarm systems
✅ Key Features & Functions:
-
🔗 Fully Addressable – Easily integrates into addressable fire alarm systems for pinpoint accuracy.
-
🔊 High Sound Output – Delivers a loud and clear alarm tone up to 100dB(A) @ 1m.
-
🎚️ Selectable Tones & Volumes – Choose from multiple tones and adjustable sound levels to suit different environments.
-
🧠 Built-In Intelligence – Monitors status and performance, ensuring optimal functionality.
-
💡 Optional Visual Indicator – Can be paired with a visual beacon for combined audio-visual warning (ideal for hearing-impaired environments).
-
🔄 Loop-Powered – Requires no external power supply, reducing wiring complexity.
-
🏢 Sleek & Compact Design – Aesthetically suitable for offices, schools, healthcare, retail, and public buildings.
-
🔒 Reliable Performance – Designed for maximum uptime and consistent operation in all indoor conditions.
Upgrade your fire detection system with C-TEC’s trusted performance — because when every second counts, your alert system must be loud, clear, and smart.
₦ 107,100.00₦ 112,200.00C-TEC Open-Area Addressable Indoor Sounder – fire alarm systems
₦ 107,100.00₦ 112,200.00 -
-
Zeta Addressable Sounder – Fire Alarm System Component
Key Benefits:
-
🔊 Loud & Clear Alerts: High-decibel output ensures alarms are heard in noisy or spacious environments.
-
🔗 Fully Addressable: Assign unique IDs to each sounder for precise control and location tracking.
-
⚙️ Customizable Tones & Volumes: Adapt the sound output to suit different building zones or risk levels.
-
⚡ Low Power Consumption: Energy-efficient design suitable for large systems with multiple devices.
-
🛠️ Easy Installation: Compatible with Zeta addressable fire systems and comes with simple wiring options.
₦ 107,100.00₦ 132,000.00Zeta Addressable Sounder – Fire Alarm System Component
₦ 107,100.00₦ 132,000.00 -











