Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Explosion Proof Manual Break Glass Unit
The Zeta flame proof siren is an explosion proof siren available in either 24V or 230V versions.
An intrinsically safe circuit is housed in the main chamber and it is duly wired up to terminal chamber through sealed bushes. The horn unit is placed on the main chamber cover and the output signals are taken through sealed coils. Neoprene ‘0’ rings are provided for the weather proof protection.
Technical Specification
- Type of protection: Flame proof – Exd T6 IP 65
- Area classification: Zone 1 & 2
- Gas Groups: Group I, II A, II B
- Apparatus Standard: IS – 2148
- CMRI Certifi cate No: CMRI / TC / S / H388
- Approvals: CCE, DGFAS
- Materials: Cast Aluminium LM 6
- Weight: 5 Kg (approx.)
- IP Protection: IP 65 to IS 13947 / 93
- Finish: Anti corrosive epoxy powder coated
- Cable Entry: 2 x ¾” ET
- Gasket: Neoprene
- Hardware: Stainless Steel
- Terminals: 4 x 2.5 sq. mm (standard) 6 x 2.5 sq. mm (for looping)
- Voltage: 24 V DC
- Output Current: 600mA Peak. Galvanically Isolated
- Power Rating: 18 Watts
- Sound Output: 106 db 900 Hz On & Off alternatively at 1C/s
- Earthing: External: 2 Nos. – M6
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZTSR/EXD24 | Flame Proof Siren (24V DC) | Datasheet |
ZTSR/EXD230 | Flame Proof Siren (230V AC) |
Dimensions | 17.0 × 3.9 × 2.4 cm |
---|
Related products
-
Zeta ID2/2/M Infinity ID2 Intelligent 2 Wire 2 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
Read more- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
HORING LIH AH-0621 UL Photoelectric Smoke Detector
Read more- UL Listed.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Twin-color LED display enables viewer to easily identify the current status of detector.
- Contacts material is highly acid-resistant and rust-resistant.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.