Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Low profile GENT sounder, ideal for use in environments where aesthetics should be discrete as possible.
The GENT S3-SN-R Electronic 2 way Sounder White is rated at 100 dBA but can be remotely configured using the HandiLink IR remote control to turn on individual sounders when in commissioning mode and to adjust the volume.
Access is no longer required to the sounder unit meaning commissioning time is cut down considerably. To enable this function, a password is required at the panel so settings cannot be changed by accident or with the intention of disrupting the environment in which it is located.
The S-cubed range of alarm sounders incorporates sound, speech and strobe effects all in one range of alarm devices. The range offers all variants in the choice of two colours (red or white), with either a shallow base version sealed to IP31 or a deep base version sealed to IP55.
All the low profile sounders have the option of an integral strobe. As an aid to commissioning there is an option to use the HandiLink IR remote controls to select sounder tones and adjust the volume remotely. This means physical access is not required to make this adjustment. This facility is only active when sounders are turned on from the alarm panel.
Key Features:
- Very low power consumption means more sounders and strobes per circuit
- The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power
- 32 sounder tones are available
- Voice enhanced sounders are available in the range
- 4 voice phrases and a bell sound are available as standard
- All sound and strobe signals are synchronised to better than +/-30mS over 20 minutes
- Sounders and strobes are compatible with 12V and 24V systems
- A third wired option allows the selection of 2 alternative sounds (ideal for class change applications)
- Products incorporate innovative design features for which multiple patents have been granted
Related products
-
C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (shallow base) Part No. BF430C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc =Â 3.8mA.
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
Zeta ID2/8/M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
-
C-TEC ActiV Conventional O-R-3-2.5-17 Base VAD c/w 96dB(A) Sounder Part No. BF432C/CC/W
Read more-
-
-
- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘C-3-8.5’ light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area).
- Impressive 96dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
-
C-TEC ActiV Conventional ‘O Class’ Base VAD c/w Voice Sounder Part No. BF455C/CC/W
Read more-
-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Provides ‘O-R-3-2.5-17’ light distribution using the same lenses and electronics as our EN54-3 & 23 certified base sounder VAD.
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc =Â 18.5mA (0.5Hz) or 30mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.