Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC Remote Status Unit, Surface Part No. EP210S
-
-
-
- DESCRIPTION
- Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
- Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
- Three monitored input connections (Hold, Abort and Mode).
- Max. 8 remote status units per EP203 panel.
- Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
Overview
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel toprovide remote system status indicationviaa 128 x 64 pixel LCD
status display.
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
Three monitored input connections (Hold, Abort and Mode).
Max. 8 remote status units per EP203 panel.
Flush remote status units(EP210F) and weather proof enclosures (BF359/1) also available.Power requirements 21-28VDC (200mA electronic fuse). Quiescent current 7mA. Auxiliary inputs Three: (1) Hold; (2) Abort; (3) Mode. A 6k8 EOL resistor must be fitted across the terminals of the last device on each monitored input circuit. Unused circuits must have the 6k8 resistor fitted at the terminals. Indicators Gen. fire; Fire Zones (x3); Gen. disablement; Hold; 1st Stage Output; 2nd Stage Output; Release Imminent (x2); Exting. Released; Abort; Gen. Fault; Man. Only; Man/Auto. Controls Extinguishant release (housed in yellow casing); Operation keyswitch (Manual only or Manual & Auto). Product dimensions (mm) 175 W x 250 H x 70 D mm. Hole required for flush mounting 156 W x 232 H x 51 D mm. Construction & finish Metal. IP Rating IP30. Weight 1.338kg.. Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%. Network specification RS485; Max. 8 remote status units (any mix) per EP203; Four wire connection (2 power, 2 data); Daisy-chain wiring
Weight | 1.598 kg |
---|---|
Dimensions | 240 × 160 × 51 cm |
Related products
-
Reset Call Point Waterproof Reset Call Point
₦23,000.00₦21,000.00Add to cartDESCRIPTION
The ZT-CP3 and ZT-CP3/WP call points are
unique in that they mimic the feel of breaking
glass whilst offering the user the benefits and
environmental advantages of a re-settable
operating element.
The CP3 uses a simple yet ingenius patented mechanism
which consists of a rigid plastic operating element and
an over centre spring mechanism. This arrangement
provides real action on operation and simulates break
glass activation. -
Gent Surface MCP (XENS-805) 470 Ohms Re-settable
₦12,000.00₦10,000.00Add to cartGent XENS-805 Surface MCP 470 Ohms Re-settable Gent Surface MCP (XENS-805) 470 Ohms Re-settable requires no hammer and is easy and safe to operate. Gent’s conventional manual call points are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are …
-
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
Zeta Infinity 8 Conventional 1 Zone Fire Alarm Panel IN1
₦139,000.00₦127,000.00Add to cartDESCRIPTION
The Infinity 8 control panel is housed in the
most attractive, modern designed, flame
retardent ABS enclosure, utilising a switch
mode power supply. It has a fully removable
front cover which improves ease of access for
cable installations.
The Infinity 8 panel can also be ordered with a metal back
box facilitating upto 7ah batteries to fit within the panel
housing. To order this version add “/M” to the end of the
model number (i.e. IN1/M, IN2/M, etc.)
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.