Control panels connect detectors, alarms, suppression systems, and monitoring stations to communicate fire detection and response signals.
Control panel activate visual, audio, and occasionally other forms of notification equipment to alert residents of an emergency situation.
There are two kinds of fire panels available today: Addressable fire alarm panel vs. conventional fire alarm panel. A conventional fire alarm control panel employs one or more circuits, connected to initiating devices wired in parallel. Addressable panels are more advanced than traditional panels, with greater information capacity and control flexibility.
Voice evacuation panels are another type of fire alarm control panel. Designed to provide outputs for speakers in the system.
A fire suppression system will be installed on important and valuable structures. The panel notifies a monitoring center of the alarm status, and people at the receiving location decide what to do next. The panel controls HVAC systems, building automation controls, access points, and elevators to isolate the fire or route workers.
-
C-TEC IP66 Rated Enclosure for EVC302GF or EVC302F Outstations Part No. BF359/1
-
- An attractive IP66 rated enclosure designed for use with a SigTEL EVC302GF or EVC302F flush mounting disabled refuge controller.
- Includes a handle and mounting plate.
- Measures 200 W x 302 H x 123mm deep.
- Textured RAL 7035 (light grey) finish.
- Also compatible with C-TEC’s EP210F remote status units.
-
-
C-TEC Output Expansion Relay Board Part No. EP212
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Mounts inside the EP203Â panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
- Reset relay switches during the panel’s reset cycle.
- Mode relay switches when the extinguishant system’s mode is changed to manual.
- Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
- Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
- Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
-
-
C-TEC System Line Terminator Part No. EP214
-
-
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
- One EP214 terminator is required per solenoid.
- Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
- Measures just 55m W x 55mm H x 22mm D.
-
-
-
-
C-TEC Remote Status Unit, Surface Part No. EP210S
-
-
-
- DESCRIPTION
- Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
- Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
- Three monitored input connections (Hold, Abort and Mode).
- Max. 8 remote status units per EP203 panel.
- Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
-
Fire Alarm Control Panel Mains Keyswitch Part No. BF319
- AÂ high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
- Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
- Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
- Fits on a standard UK 47mm flush or surface mount back box.
- Supplied with 2 x M3.5 25mm fixing screws.
- BS EN60669-1 compliant.
- Always read the full installation and operating instructions supplied with the unit before use.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control PanelÂ
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
🛑Orisong/Concept Plus Smoke Detector
✅ Rapid Smoke Detection
✅ Low Power Consumption
✅ Durable and Easy Maintenance
✅ Ideal for Residential & Commercial Use🛒 Available now at Trends Ventures Ltd
₦ 6,825.00₦ 6,925.00Buy now🛑Orisong/Concept Plus Smoke Detector
₦ 6,825.00₦ 6,925.00 -