Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
- You cannot add that amount of "Solo Test Gas A10" to the cart because there is not enough stock (0 remaining).
-
Gent MAINS POWERED DUA 60 Watt Mains Powered Distributed Amplifier (COMPACT-MAINS-DAU)
The Gent MAINS POWERED DUA is a new addition to Compact Voice increasing the design capability and flexibility of the system. The new Amplifier Unit allows connection to a comprehensive range of standard 100 volt loudspeakers meeting the needs of any VA application at the same time as maintaining the advantages already delivered by the Compact Voice system. The new Amplifier Unit allows connection to a comprehensive range of standard 100 volt loudspeakers meeting the needs of any VA application at the same time as maintaining the advantages already delivered by the Compact Voice System.
-
Zeta ID2/2/M Infinity ID2 Intelligent 2 Wire 2 Zone Fire Panel in Metal Enclosure
DESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
-
ZT-ST5-5 Zeta 3V Standalone Smoke Detector (5 Year Life)
They feature VdS and UL-approved photoelectric sensing components with precise smoke detection and long life operation (5 year life with a 3V lithium battery) or (10 years with a 3V long life lithium battery). A proved quality with 10 million pieces installed over the world. Russian standard model available too.
-
ZT-ST5-10 Zeta 3V Standalone Smoke Detector (10 Year Life)
They feature VdS and UL-approved photoelectric sensing components with precise smoke detection and long life operation (5 year life with a 3V lithium battery) or (10 years with a 3V long life lithium battery). A proved quality with 10 million pieces installed over the world. Russian standard model available too.
-
ZT-TH5 Zeta 9V Standalone Heat Detector (1 Year Life)
The ZT-ST5 & ZT-ST5/10 stand-alone photoelectric residential smoke alarms are NF approved and can be calibrated to either UL, BSI or VdS requirements.
-
Zeta ZRPB/R Conventional Raptor Weatherproof Sounder Beacon
Zeta ZRPB/R Conventional Raptor Weatherproof Sounder Beacon has a coverage pattern of W 5.1 – 7.25 and the sounder part has 22 selective tones. It has been designed to make an “electronics free” first fix and is available in red or white.
-
ZETA ZT-CP3/Y Gas Extinguishing Call Point
- Gas release manual call point in yellow housing
- Single pole changeover
-
ZETA ZT-CP3/B| Abort Call Point
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA Call Point Protective Cover | CP3-CV
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA CP3-FMB/B | Abort Call Point Flush Mount Bezel
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.