Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
C-TEC Manual ‘Crack Glass/No Break’ Call Point, flush/surface Part No. BF370FR
- Certified to EN54 Parts 11 (LPCB)Â and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
-
C-TEC Output Expansion Relay Board Part No. EP212
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Mounts inside the EP203Â panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
- Reset relay switches during the panel’s reset cycle.
- Mode relay switches when the extinguishant system’s mode is changed to manual.
- Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
- Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
- Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
-
-
C-TEC System Line Terminator Part No. EP214
-
-
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
- One EP214 terminator is required per solenoid.
- Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
- Measures just 55m W x 55mm H x 22mm D.
-
-
-
-
C-TEC Remote Status Unit, Surface Part No. EP210S
-
-
-
- DESCRIPTION
- Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
- Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
- Three monitored input connections (Hold, Abort and Mode).
- Max. 8 remote status units per EP203 panel.
- Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
-
Fire Alarm Control Panel Mains Keyswitch Part No. BF319
- AÂ high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
- Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
- Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
- Fits on a standard UK 47mm flush or surface mount back box.
- Supplied with 2 x M3.5 25mm fixing screws.
- BS EN60669-1 compliant.
- Always read the full installation and operating instructions supplied with the unit before use.
-
C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM
- A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
- Up to 30 BF365IM modules per BF365SC controller.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
-
C-TEC Remote LED Indicator Part No. BF318
- AÂ high-quality remote LED indicator specifically designed for use in fire alarm systems.
- Incorporates a high intensity, wide-angle red LED which is clearly visible from the front of the plate when active.
- Ideal for indicating the activation of hidden or out of-sight fire detectors, etc.
- Includes a white ‘write on’ area allowing installers to add equipment locations.
- Fits on standard UK 16mm flush or surface mount back boxes.
- Download datasheet
-
C-TEC Single Gang Locking Jack Socket for BF320 Part No. BF320JP
- Can be used in conjunction with a BF320 vibrating pillow pad to warn the hearing impaired of a potential fire alarm or evacuation alert condition.
- Compatible with all C-TEC fire alarm and evacuation alert systems.
- Locking mini-XLR connector and plug arrangement helps prevent accidental pillow pad removal.
- Line monitored for disconnection via an internal 6k8Ω end of line resistor (selectable at the BF320JP).
- Selectable 6K8 (pillow pad) or 27K (jack socket) end of line monitoring options for fire alarm or evacuation alert system use.
- Can be used on systems with a 10-30V DC voltage range
- Fits on a standard UK 25mm back box.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control PanelÂ
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.