Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
ZETA ZT-CP3/B| Abort Call Point
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA Call Point Protective Cover | CP3-CV
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA CP3-FMB/B | Abort Call Point Flush Mount Bezel
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
ZETA Call Reset Key | CP3-KEY
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
Zeta Intrinsically Safe Optical Smoke Detector (ZIS-OSD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. monitoring mode current: ≤ 60 μA
- Alarm current: 20 mA
- Detectable test fires: TF1 to TF5 and TF8
- Operating temperature range: from -25 o C up to +55 o C
- Relative humidity: up to 95 % at 40 o C
- Colour: Black
- Dimensions with base: 115 dia. x 54 mm
- Weight: 0.15kg
-
Zeta Intrinsically Safe Flame Detector (ZIS-FLD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. quiescent current: 100 μA
- Alarm current at 20 V DC: 20 mA
- Detection distance: 17m max. (2nd class of sensitivity)
- View angle: 120o
- Wave detected: UV
- Operation temperature range: from -25 oC up to +55 oC
- Relative humidity: up to 95 % at 40 oC
- Colour: Black
- Dimensions: 107 dia. x 60 mm
- Weight: 0.45kg
-
ZETA Base for Intrinsically Safe Flame Detector (ZIS-33)
Technical Specification
- Diameter of installation cable wires: 2mm max; n/a
- Spacing between installation holes: 140mm
- Dimensions: Ø118 x 47mm
-
ZETA ZIS-40 | Base for Intrinsically Safe Smoke Detector
Technical Specification
- Diameter of installation cable wires (ZIS-40; ZIS-40/W): 1mm max; n/a
- Spacing between installation holes (ZIS-40; ZIS-40/W): 63mm; 127mm
- Dimensions (ZIS-40; ZIS-40/W): Ø107 x 28.5mm; Ø112 x 26mm
- Combined height: 43mm
- Weight: 0.1kg
-
ZETA ZIS-40/W | Optional ZIS-40 Base Mounting Attachment With PG-7 Sealing Gland
Technical Specification
- Diameter of installation cable wires (ZIS-40; ZIS-40/W): 1mm max; n/a
- Spacing between installation holes (ZIS-40; ZIS-40/W): 63mm; 127mm
- Dimensions (ZIS-40; ZIS-40/W): Ø107 x 28.5mm; Ø112 x 26mm
- Combined height: 43mm
- Weight: 0.1kg
-
ZETA 400-210R| Fire Alarm Safety Isolator Switch
Technical Specification
- Working Voltage : 250AV
- Colour : Red or White
- Switch Contact Rating : Double Pole – 250V AC 4Amp
- FUSE Rating : Max – 6A Fast (20mm) supplied
- Enclosure Material : RoHS Compliant FR ABS
- Weight : 175g
-
ZETA 400-210W | Fire Alarm Safety Isolator Switch
Technical Specification
- Working Voltage : 250AV
- Colour : Red or White
- Switch Contact Rating : Double Pole – 250V AC 4Amp
- FUSE Rating : Max – 6A Fast (20mm) supplied
- Enclosure Material : RoHS Compliant FR ABS
- Weight : 175g
-
ZETA SD-830A 24V DC Autodialler Without Enclosure
- Dials stored telephone numbers when alarm input is received from a fire system
- Store up to 6 telephone numbers
- Operates on 24V power