Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
Gent Detector base complete with Diode (805590-D)
DESCRIPTION
Gent 805590-D Conventional Diode Detector BaseÂ
Manufactured by Gent, the Gent 805590-D ES S-Quad Detector Base with Diode is designed for use with the Gent Xenex Control Panel, as well as with the ES S-Quad range of Conventional Detectors.
The ES Detect range replaces the Vision 20/20 range.
-
GENT Rate of rise heat detector (800271)
RATE-OF-RISE HEAT DETECTOR:
Automatic heat detector with fast semiconductor sensor to
guarantee reliable detection of fires with rapidly rising temperatures
and integrated fixed temperature function for the detection of fires
with slowly rising temperatures. -
Gent Fixed heat detector-Class B(800177)
FIXED HEAT DETECTOR CLASS B:
For increased operating temperature according to EN 54-5 class B
The ES Detect automatic detector is an
non-addressable detector specifically
designed for operation on conventional
systems.
The range not only includes intelligent
algorithms for fire detection but also a
wide range of different types of detectors -
Gent Fixed heat detector (800171)
DESCRIPTION
Gent 800171 Conventional S-Quad Fixed Heat Detector
Manufactured by Gent, the Conventional S-Quad Fixed Heat Detector 800171 is an automatic heat detector with fast semi-conductor sensor for the reliable detection of fires with strong heat development. Process detector with decentralized intelligence, automatic function self-alarm and operating data storage and alarm indication. A remote indicator can also be connected
-
Gent Change Over Contact MCP
Gent Change Over Contact is a conventional manual call point, designed to provide a manual
alarm interface to conventional fire alarm control panels. All call points
are supplied in the standard red color and are available in semi-flush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated. -
Gent Key Operated, Surface Mounted C/W BackBox (XENS-807)
Our conventional manual call points are designed to provide a manual
alarm interface to conventional fi re alarm control panels. All call points
are supplied in the standard red colour and are available in semi-fl ush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated. -
FS24X-911-23-6: QuadBandâ„¢ IR3+ Detector (Aluminum)
FS24X provides wideband Multi-Spectrum Triple IR (IR/IR/IR/Visible) flame detection. It is part of our FSX family of
advanced technology Electro-Optical fire detectors. Using our patented* WideBand IRâ„¢, WideBand 4.3 micron IRâ„¢, and
Visible detection technology, the FS24X sets the standard for flame detection. Sophisticated software algorithms and dual
microprocessors ensure that the FS24X has the highest fire detection performance combined with optimal false alarm
rejection.
The WideBand IRâ„¢ Infrared technology using high-speed solid-state Quantum sensors allows detection of all types of fires,
hydrocarbon and non-hydrocarbon, in all weather conditions. -
Texecom EXD Buzzer TCA-0005
EXD Buzzer
The Exd Buzzer is an explosion proof buzzer designed
for use in hazardous areas where a distinctive signal is
required. Certified to ATEX II 2G Exd e IIC T6, it is suitable for
use in Zone 1 and Zone 2 areas.
Producing a tone with low frequency, it cuts through
background noise more effectively than many other
devices of a similar output.
Mounted in a rugged reinforced polyester case and
weatherproof to IP66, it is suitable for use in the most
arduous conditions. -
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent’s range of conventional manual call points are designed to provide a manual alarm interface to conventional fi re alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
-
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Gent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
C-TEC MARINE ISOLATOR BASE [SIL2] 45681-211MAR
The Marine Isolator Base is unique and designed to only accept the marine isolator.