Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
Zeta Intrinsically Safe Flame Detector (ZIS-FLD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. quiescent current: 100 μA
- Alarm current at 20 V DC: 20 mA
- Detection distance: 17m max. (2nd class of sensitivity)
- View angle: 120o
- Wave detected: UV
- Operation temperature range: from -25 oC up to +55 oC
- Relative humidity: up to 95 % at 40 oC
- Colour: Black
- Dimensions: 107 dia. x 60 mm
- Weight: 0.45kg
-
Zeta Intrinsically Safe Optical Smoke Detector (ZIS-OSD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. monitoring mode current: ≤ 60 μA
- Alarm current: 20 mA
- Detectable test fires: TF1 to TF5 and TF8
- Operating temperature range: from -25 o C up to +55 o C
- Relative humidity: up to 95 % at 40 o C
- Colour: Black
- Dimensions with base: 115 dia. x 54 mm
- Weight: 0.15kg
-
ZETA Call Reset Key | CP3-KEY
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
ZETA CP3-FMB/B | Abort Call Point Flush Mount Bezel
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
ZETA Call Point Protective Cover | CP3-CV
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA ZT-CP3/B| Abort Call Point
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA ZT-CP3/Y Gas Extinguishing Call Point
- Gas release manual call point in yellow housing
- Single pole changeover
-
Zeta ZRPB/R Conventional Raptor Weatherproof Sounder Beacon
Zeta ZRPB/R Conventional Raptor Weatherproof Sounder Beacon has a coverage pattern of W 5.1 – 7.25 and the sounder part has 22 selective tones. It has been designed to make an “electronics free” first fix and is available in red or white.
-
ZT-TH5 Zeta 9V Standalone Heat Detector (1 Year Life)
The ZT-ST5 & ZT-ST5/10 stand-alone photoelectric residential smoke alarms are NF approved and can be calibrated to either UL, BSI or VdS requirements.
-
ZT-ST5-10 Zeta 3V Standalone Smoke Detector (10 Year Life)
They feature VdS and UL-approved photoelectric sensing components with precise smoke detection and long life operation (5 year life with a 3V lithium battery) or (10 years with a 3V long life lithium battery). A proved quality with 10 million pieces installed over the world. Russian standard model available too.