Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
ZETA ZS2-CS/R Securetone 2 Red Conventional Sounder
- Four different tones are available and selected by jumpers.
- The Sound level can be adjusted if required, using the potentiometer.
- The complete range is composed of 3 varieties in both base and wall mounted versions: Beacon, Sounder and combined Sounder/ Beacon.
-
Zeta Conventional 6-inch Fire Alarm Bell ZT-BELL/6
The Zeta motorised fire alarm bells combine styling and functional efficiency. They incorporate a low power rotary centrifugal mechanism, which gives a high sound output with low current consumption at 24V dc.
-
ZETA 10 Inch Intrinsically Safe Gong Bell (ZTB8B/EXD/24)
The Zeta flame proof siren is an explosion proof siren available in either 24V or 230V versions.
The Zeta flame proof gong bell is an explosion proof gong bell with a terminal chamber. A highly reliable electric circuit is housed inside to control the frequency of the gong operating spindle. The operating spindle and dish are made out of stainless steel thereby ensuring a long life. The electric circuits are connected to terminals in the terminal chamber through nipple. The covers are provided with neoprene gaskets for weatherproof protection.
-
ZETA Explosion Proof Manual Break Glass Unit (ZTBG-EXD)
The ZTBG/EXD explosion-proof fire alarm control is a station with an integral terminal chamber. A push button actuator with a mushroom head is provided in the main chamber. This actuator is in constant contact with a glass cover which when broken activates the alarm. A single contact element in the main chamber is wired to terminals in the terminal chamber through sealed explosion proof bushings. The alarm station is provided with gaskets for weather proof protection.
-
ZETA FEUV2000 | Fyreye Ultra-Violet Flame Detector With Base
The Fyreye ultra-violet flame detector is particularly suited to applications where flames can be expected to develop initially rather than smoke. This is typically due to the nature of the materials being protected for instance camera film, computer, audio & video tapes or disks.
-
ZETA ZP-CP4/G | CP4 Conventional Surface Mount Manual Call Point, Green
Technical Specification
- Current Rating:Â 3 Amps 12 – 24V DC
- Low Current Rating:Â 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA ZP-CP4/W | CP4 Conventional Surface Mount Manual Call Point, White
Technical Specification
- Current Rating:Â 3 Amps 12 – 24V DC
- Low Current Rating:Â 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA ZP-CP4 | CP4 Conventional Surface Mount Manual Call Point, Red
Technical Specification
- Current Rating:Â 3 Amps 12 – 24V DC
- Low Current Rating:Â 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA CP3-FMB/R | Abort Call Point Flush Mount Bezel
The Zeta CP3-FMB is a flush mounting bezel for the ID2 & CP3 manual call points.