Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
HORING LIH AH-0621 UL Photoelectric Smoke Detector
- UL Listed.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Twin-color LED display enables viewer to easily identify the current status of detector.
- Contacts material is highly acid-resistant and rust-resistant.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
HORING LIH AH Q05 EN Combination Smoke and Heat Detector
- EN54-7 & EN54-5 Approval.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
HORING LIH NDKB1 Carbon Monoxide Detector
- Test button for alarm simulation.
- Green LED to confirm the unit is under normal operation.
- Two modes of the Alarm LED in visible and audible warning to easily identify the status.
- Three modes of the Fault LED in visible and audible warning to easily identify the causes.
- Triple-color LED display with high brightness enables viewers to easily identify the status of detector.
- A set of relay output: COM. N.O. N.C. (NDKB1)
-
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control PanelÂ
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).
-
C-TEC Single Gang Locking Jack Socket for BF320 Part No. BF320JP
- Can be used in conjunction with a BF320 vibrating pillow pad to warn the hearing impaired of a potential fire alarm or evacuation alert condition.
- Compatible with all C-TEC fire alarm and evacuation alert systems.
- Locking mini-XLR connector and plug arrangement helps prevent accidental pillow pad removal.
- Line monitored for disconnection via an internal 6k8Ω end of line resistor (selectable at the BF320JP).
- Selectable 6K8 (pillow pad) or 27K (jack socket) end of line monitoring options for fire alarm or evacuation alert system use.
- Can be used on systems with a 10-30V DC voltage range
- Fits on a standard UK 25mm back box.
-
C-TEC Remote LED Indicator Part No. BF318
- AÂ high-quality remote LED indicator specifically designed for use in fire alarm systems.
- Incorporates a high intensity, wide-angle red LED which is clearly visible from the front of the plate when active.
- Ideal for indicating the activation of hidden or out of-sight fire detectors, etc.
- Includes a white ‘write on’ area allowing installers to add equipment locations.
- Fits on standard UK 16mm flush or surface mount back boxes.
- Download datasheet