Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
GENT Notifier Sounder Base Conventional NBS4
Non-Addressable Detector Base Sounder, 4 Tone, Suitable for fire detectors with 60mm mounting centres. approved to EN54-3.
If required the SC085 (white) lid to be ordered separately.
• 4 Tone Sounder
• High sound output, low current consumption
• High reliability and stable performance
• Volume control
• Lid accessory available to enable vertical installation
• Designed and approved to EN54-3
• Market specific tone set available -
GENT-S3-S-VAD-HPR 2 way Sounder/Strobe Red Body Red Lens
Honeywells Sounder Beacon, designed and approved to meet both EN54-3 and EN54-23, is ideal for applications where a dual purpose audible and visual alarm device is required. A new folded horn design, high output LEDs, advanced optics and an innovative lens design, provides outstanding sound output and omni-directional light coverage at low current draw
₦ 42,000.00Buy now -
-
-
-
Gent M1A-R470FG-G017-01 Flush MCP 470 Ohms
Manual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
-
Gent 07011-40 Optical Beam Reflective 50-100m
– Combined transmitter and receiver unit in one discrete unit
– Range 50-100 Metres
– Low current consumption
– Automatic self check drift compensation
– Selectable sensitivity/threshold levels
– Selectable latching / non latching fire alarm
– LED indicators to aid the alignment process
– Optional Low Level Test Unit for UL models only₦ 350,000.00Buy nowGent 07011-40 Optical Beam Reflective 50-100m
₦ 350,000.00 -
Gent 17801-01 Surface Mount Base with Dual Diodes
- Key Features
- Common to all Gent series detectors
- Automatic locking option
- Head out continuity monitoring
- Easy to install
- Key Features