Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.

Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.

Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.

  • C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%

     570,000.00 600,000.00
  • C-TEC Flushing Mount Remote Status Unit Part No. EP210F

          • Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.

          • Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.

          • Three monitored input connections (Hold, Abort and Mode).

          • Max. 8 remote status units per EP203 panel.

          • Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.

     300,000.00 320,000.00
  • C-TEC ActiV Optical Smoke Detector Part No. C4416

        • DESCRIPTION

        • A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.

        • Manufactured by C-TEC in the UK.

        • Third-party certified to EN54-5 by Intertek.

        • Wide 6-33V DC operating voltage.

        • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.

        • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.

     28,000.00 30,000.00
  • C-TEC Economy Status Unit Part No. EP211

        • Designed to connect to the EP203 Automatic Extinguisher Panel to provide remote system status indication via three LEDs.

        • Includes a mode (auto/manual) keyswitch.

        • Mounts on a standard UK single gang 25mm flush or surface back box.

        • Max. 8 economy status units per EP203 panel.

     156,000.00 159,000.00

    C-TEC Economy Status Unit Part No. EP211

     156,000.00 159,000.00
  • C-TEC Single Gang Surface Interface Plate, shallow (20mm) Part No. NCP-23

  • C-TEC Single Gang Surface Interface Plate, deep (25mm) Part No. NCP-24

    • Allows standard UK single gang plated products to be fixed to most European style back boxes (square and round variants).
    • Adapts to most European fixing centres – see video for further details.
    • Multiple variants available – options include single gang shallow (NCP23), single gang deep (NCP24), double gang shallow (NCP25) and double gang deep (NCP26).
    • Designed to match C-TEC’s existing plastics and colours.
    • Tough and durable.
    • Can also be surface mounted directly to a wall.
  • APOLLO AlarmSense Open Area Sounder IP65

    • A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.

    • IP65 rated.

    • Up to 99dB(A) sound output at 1m.

    • Ultra-bright red LED.

    • Device locking facility.

    • Max. five Open-Area Alarm Devices per AlarmSense zone.

     99,000.00 100,000.00

    APOLLO AlarmSense Open Area Sounder IP65

     99,000.00 100,000.00
  • AlarmSense Standard Rate of Rise Heat Detector

    When every second counts, trust the technology that responds fast and reliably. The AlarmSense Standard Rate of Rise Heat Detector is designed to detect rapid temperature increases, providing early warning of fire without false alarms triggered by daily heat variations.

    Perfect for residential, commercial, and industrial applications, this intelligent device works seamlessly with AlarmSense two-wire systems—offering an efficient and cost-effective fire safety solution.

    Rapid Heat Detection
    Highly Accurate and Reliable
    Easy Installation with Two-Wire Technology
    Ideal for Kitchens, Warehouses, and Utility Spaces

    At Trends Ventures Limited, your safety is our priority. Equip your buildings with advanced fire detection technology today and ensure peace of mind for tomorrow.

     22,000.00 24,000.00
  • AlarmSense Optical Smoke Detector

    AlarmSense Optical Smoke Detector – Reliable Fire Safety by Trends Ventures Limited

    Stay protected with the AlarmSense Optical Smoke Detector, built for fast, accurate smoke detection. Perfect for homes, offices, and commercial buildings, it integrates easily into AlarmSense two-wire systems for efficient installation.

    Key Features:

    • Fast response to slow-burning fires

    • Reduced false alarms

    • Compatible with AlarmSense control panels

    • Easy installation & low maintenance

    • LED status indicator for clear alerts

    Now available at Trends Ventures Limited – your trusted fire and safety partner.

     23,000.00 25,000.00

    AlarmSense Optical Smoke Detector

     23,000.00 25,000.00
  • C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     295,000.00 300,000.00
  • C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     222,000.00 250,000.00
  • C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     195,000.00 200,000.00
chat with us
1
Select your currency
NGN Nigerian naira

Main Menu