Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.

Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.

Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.

  • Zeta Beam Xtra Motorised Reflective Beam Smoke Detector c/w extender Kit

    DESCRIPTION

    Developed to overcome the problems of
    old outdated technology in beam detection,
    this motorised beam now means that beam
    detection can be used reliably to produce cost
    effective solutions for protecting large open
    areas.

     504,500.00 550,000.00
    Buy now
  • C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%

     570,000.00 600,000.00
    Buy now
  • Gent Xenex 2 Zone Conventional Fire Alarm Panel

    01

    FEATURES

      • Gent Xenex 13270-02LB

      • 2 sounder circuits

      • 1A sounder circuit max load

      • Conforms to EN54: parts 2 & 4

      • On-board relay

      • Fire and fault relay expansion card optional

      • Easy configuration

      • Class change input

     624,750.00 630,000.00

    Gent Xenex 2 Zone Conventional Fire Alarm Panel

     624,750.00 630,000.00
    Buy now
  • Gent 4 ZONE CONVENTIONAL PANEL

    DESCRIPTION

    Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

    BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.

    Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.

     708,750.00 720,000.00

    Gent 4 ZONE CONVENTIONAL PANEL

     708,750.00 720,000.00
    Buy now
  • Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds (VIG-BNG-RW)

    Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds

    The BACnet protocol is a Standard (Ansi/Ashrae 135-2004). With the Gent BACnet Gateway Assembly, devices on Vigilon fire alarm control panels are represented as BACnet objects to the BACnet client. The user subscribes to Event Notification objects from the FACP as required and the BACnet device receives events from objects on the FACP as a result of the subscription.

     825,000.00
    Buy now
  • Gent Xenex 13270-08LB 8 Zone Conventional Fire Alarm Panel

    The Gent Xenex 13270-08LB fire alarm panel is a highly cost-effective conventional option for building premises requiring coverage to four zones.

    With eight alarm sounder circuits, repeater panel output, remote evacuation control and one-man test and commissioning, Xenex by Gent is a leader in conventional panel technology.

     846,825.00 850,000.00
    Buy now