Category
- Uncategorized
- apollo
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
-
Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
-
Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
-
Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00
Category: Fire Suppression system
Showing all 5 results
-
C-TEC Fire Alarm Automatic 3+1 Extinguisher Panel Part No. EP203
₦330,000.00₦326,500.00Add to cartTechnical Specifications
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
Mains supply 230V 50/60Hz.
Mains rated current 810mA max.
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 3 x 200mA.
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95% -
Out of Stock
QSP-120 Multi-Hazard Suppression Control Panel
Read moreQSP-120 Multi-Hazard Suppression Control Panel Characteristics Panel and manual pull station count-down simultaneously. Discharge delay timer setting (20~999 seconds). Cross-zone detection confirmation makes better stability. Built-in phone jacks on both panel and manual pull station. Expandable to 5 loops (10 zones) detection sections. Each section has manual/auto operation mode. Wiring trouble inspection. Through dipswitch …
-
Out of Stock
QSP-32 Fire Alarm Manual Pull Station
₦0.00Read moreCharacteristics Emergency Start/Stop switch, Auto/Manual key switch. Power LED, Releasing LED, Start LED, Stop LED, Auto LED, and Manual LED. Digital release countdown. Specifications Model QSP-32 Supply Voltage 24V DC Material 1.2mm stainless steel Color Red Dimensions 160mm(H) x 165mm(W) x 50mm(D) Catalogue QSP-32 Catalogue
-
Zeta EX-PRO Premier Fire Extinguishing Control Panel
₦355,000.00₦310,000.00Add to cartThe EX Pro is the latest modern designed extinguishing panel from Zeta Alarm Systems, fully complying with EN54 parts 2 & 4, and EN 12094 part 1. Featuring a blue 4 x 20 LCD display with a list of extra features such as memory log of fire, fault and system events, adjustable flood times and …
Zeta EX-PRO Premier Fire Extinguishing Control PanelRead More
-
ZETA Premier EX Pro Fire Alarm Output Expansion Relay PCB | EX-OER8
Read morePremier EX Pro Output Expansion Relay PCBs The EX-OER output expansion relay board can be mounted inside the EX Pro to provide voltage-free changeover relay contacts for reset, mode, discharged, abort and additional 1st stage, 2nd stage output and extract fan output. One unit can be used. Model Number Description Datasheets & Manuals EX-OER8 Premier …
ZETA Premier EX Pro Fire Alarm Output Expansion Relay PCB | EX-OER8Read More
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read MoreBlog Updates

