Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
- Promotions
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00Original price was: ₦6,250,000.00.₦6,170,000.00Current price is: ₦6,170,000.00. -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00Original price was: ₦22,000.00.₦18,500.00Current price is: ₦18,500.00. -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00Original price was: ₦462,000.00.₦458,000.00Current price is: ₦458,000.00. -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00Original price was: ₦20,000.00.₦19,000.00Current price is: ₦19,000.00. -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00Original price was: ₦4,600,000.00.₦4,500,000.00Current price is: ₦4,500,000.00. -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00Original price was: ₦23,500.00.₦21,500.00Current price is: ₦21,500.00. -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00Original price was: ₦13,000.00.₦11,000.00Current price is: ₦11,000.00.
Apollo (Fire Alarm) AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
Approvals/certifications | Certified to EN54- by by UL International (UK) Limited. |
Application/operation | Designed to be ceiling mounted with an AlarmSense fire detector. Red and White caps available for stand alone use. |
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 18-33VDC (sounders active); Less than 15VDC (sounders off). |
Quiescent current | Less than 20µA @ 12VDC. |
Nominal SPL (Sound Pressure Level) | 87dB(A) max (high volume setting); 70dB(A) nominal (low volume setting). |
Alarm current | 5mA (sounder active current at 24V). |
Product dimensions (mm) | 115mm diameter x 40mm deep (without optional AlarmSense detector). |
Construction & finish | White/clear polycarbonate. Red and white caps available for stand alone use. |
IP Rating | TBC. |
Weight | 150g. |
Related products
-
C-tec Fire Alarm 24V 5A EN54-4 Switch Mode PSU Part No. BF562-5
Read more- Certified to EN54-4/A2 by the LPCB and VdS.
- A powerful 24V 5A switch mode/digital hybrid PSU that can be customised* to suit your exact requirements – see More Information tab for details.
- Plastic cover on PSU PCB guards against touching live parts.
- Includes a single-pole voltfree changeover relay that switches for any fault condition.
- Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
- Two selectable battery charge currents.
- Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
- Mains fail simulation mode.
- Improved on-board temperature sensor with optional remote sensor.
- Electronic functions comply with EN50131-6 grades 1-4 for security applications.
- BF562-5/E encased version also available.
-
APOLLO Addressable Fire Alarm XPERT 7 BASE 4″ – ISOLATING
Read moreThe base senses short-circuit faults on Discovery loops and spurs and minimises disruption from short circuits.
- Detects wiring short-circuits
- High brightness LED
- Up to 20 detectors or their equivalent load, may be installed between isolating bases
-
Gent Fire Alarm VCS-PSU-N Compact Replacement PSU
₦0.00Read moreDESCRIPTION
Gent VCS-PSU-N Compact Replacement PSU
The VCS-PSU-N Replacement PSU is designed for use with the Gent Nano and Gent Compact controls panels.
-
Gent Fire Alarm G017-01 Weatherproof Manual Call Point W1A-R470SF
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.