Category
- Uncategorized
- apollo
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
-
Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
-
Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
-
Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦5,600,000.00₦5,455,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00
Optimize Linear Beam Detection with Gent Fire Alarm Angle Bracket + Base: Certified Reliability and Easy Installation!
CompareEnhance your linear beam detection system with the Gent Fire Alarm Angle Bracket + Base, designed for use in areas where the S4-34740 beam detector cannot be installed to a vertical surface or where the beam path is not perpendicular to the installation surface. This bracket and base combination, supplied with a pre-installed S-Quad base, offers a flexible solution for optimal beam alignment in various applications.
1: Flexible Installation Design
Discover the versatility of the Gent Fire Alarm Angle Bracket + Base, providing a flexible installation design for areas where traditional vertical installation is impractical. This solution accommodates unique installation surfaces and beam path requirements.
2: Optimized Beam Alignment
Ensure precise beam alignment with the Angle Bracket + Base combination. The pre-installed S-Quad base, coupled with features like ‘one man alignment and commissioning’ and auto-gain setting, guarantees optimum alignment with ease.
3: Enhanced Linear Beam Detection
Elevate your linear beam detection capabilities with Gent’s S-Quad Beam Sensors. This market-leading device offers enhanced solutions where point detection is not practical or economical. Power and control via the loop streamline the installation process.
4: Key-Operated Maintenance
Experience enhanced maintenance with the key-operated test feature. This function simulates beam obscuration during a fire, ensuring the beam detector’s reliability and performance. Trust in a solution designed for long-term efficiency.
5: Certified Reliability
Rely on the certified reliability of the Gent Fire Alarm Angle Bracket + Base. Certified to EN54 parts 12 and 17, this solution meets stringent industry standards, assuring quality, safety, and compliance.
6: Easy Installation with Pre-Installed Base
Simplify installation with the pre-installed S-Quad base. The Fire Alarm Angle Bracket + Base offers convenience and efficiency in setup, reducing installation time and effort.
7: Market-Leading Device Features
Explore the market-leading features of Gent’s S-Quad Beam Sensors, including one-man alignment and commissioning. The auto-gain setting ensures the optimum alignment is achieved, contributing to the device’s exceptional performance.
Related products
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
Out of Stock
Gent Fire Alarm Red IP65 deep base wall and ceiling mount sounder. Deep base included.(CWSO-RR-W1)
Read moreHoneywell’s Non-Addressable sounder is a high quality device
designed to alert building occupants of an emergency. The product
features a new folded horn design which provides outstanding
sound output at low current draw. With its modern design, global
tone set and extensive installer-friendly features, the sounder is
the logical choice for specifiers, installers and distributors. -
Out of Stock
Gent Fire Alarm VCS-PSU-N Compact Replacement PSU
₦0.00Read moreDESCRIPTION
Gent VCS-PSU-N Compact Replacement PSU
The VCS-PSU-N Replacement PSU is designed for use with the Gent Nano and Gent Compact controls panels.
-
C-TEC FP 2 Zone Conventional Fire Alarm Panel | Part Number: FF382-2
₦82,000.00₦79,000.00Add to cart- Installer-friendly design.
- Robust metal enclosure with heavy-duty base connections.
- One conventional Zone circuit
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read MoreBlog Updates

Reviews
There are no reviews yet.