Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00Original price was: ₦6,250,000.00.₦6,170,000.00Current price is: ₦6,170,000.00. -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00Original price was: ₦22,000.00.₦18,500.00Current price is: ₦18,500.00. -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00Original price was: ₦462,000.00.₦458,000.00Current price is: ₦458,000.00. -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00Original price was: ₦20,000.00.₦19,000.00Current price is: ₦19,000.00. -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00Original price was: ₦4,600,000.00.₦4,500,000.00Current price is: ₦4,500,000.00. -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00Original price was: ₦23,500.00.₦21,500.00Current price is: ₦21,500.00. -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00Original price was: ₦13,000.00.₦11,000.00Current price is: ₦11,000.00.
Zeta ZIOU/230 Interface Module Loop Powered (5.0A Rating)
The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.
The connection to the input is monitored for fault (open or short circuit) and Alarm conditions.
The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System, for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems, etc.
Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output.
The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED. An 8 way D.I.L switch is provided to configure the module’s address.
This value can be set in the range 1 to 125. The following programmable functions are available: Input Activation Mode, Delayed Input Alarm Activation, Output Delayed Activation.
The Simplicity CO 8 range is designed to detect & monitor CO concentrations in places such as warehouses, car parks, tunnels and enclosed buildings where forklifts, cars and delivery trucks can produce deadly amounts of carbon monoxide, in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.
Key Features
- Fast Activation Response
- Loop Powered
- Five Status LEDs provided
- Low Power Consumption
- Module features an integral short-circuit loop isolator
- Single mains rated relay contact
Weight | 1 kg |
---|
Related products
-
Out of Stock
APOLLO Addressable Fire Alarm DISCOVERY UL OPEN-AREA SOUNDER VID – RED BODY (RED FLASH)
Read moreDiscovery UL Open-Area Sounder Visual Indicator with red body and red flash.
- UL 464 Certified
- 15 Pairs of Tones (EN54-3 Sounder)
- 7 Volume Levels
- Visual Indicator Beacon (Red-Flash)
- Discovery (works on XP95 & CoreProtocol)
-
Out of Stock
Apollo Addressable Fire Alarm E-Z Fit Base – 6″ Ultra-Low Profile Detector Mount
Read more- Four-wire base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains a ground wire terminal
-
Out of Stock
CTEC Fire Alarm CONVENTIONAL CFP Relay Output Card (Reset, Fault, Aux. & Remote Relay Outputs)
₦0.00Read more-
Product dimensions (mm) 82 W x 125 H x D 23mm. Weight 64g. Properties Single pole changeover contacts; Rated at 1A 50V; 50V Isolation between relays, contacts and CFP & relays; 27mA active relay coil current @ 27.6V supply.
-
-
Out of Stock
Gent Fire Alarm G017-01 Flush MCP 470 Ohms M1A-R470FG
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.