  • Loop-powered (60 devices per loop as maximum)
  • Hand addressed using the 8-way dip switch OR
  • Softly addressed using our handheld MKII
  • Programmer (part no. 48-004)
  • Equipped with short circuit line isolator
  • Extensive front unit indications
Compare

Fyreye MkII Addressable fire alarm Input/Output Module – Control and Monitor with Ease

Elevate Your Fire Safety Game with the Zeta Fyreye MkII Addressable fire alarm Input/Output Module With Isolator (ZAIO-MI) – A Powerhouse of Control and Monitoring!

Section 1: Advanced Control and Monitoring

The ZAIO-MI is your all-in-one solution, combining input and output capabilities within a sleek 2-gang box-sized enclosure. With a robust electronic circuit board safeguarding against installation mishaps, this module ensures uninterrupted performance. Designed to meet the stringent EN54-18 2005 and EN54-17 2005 standards, it’s your ticket to enhanced fire safety.

Section 2: Versatile Applications

Imagine a device that not only monitors inputs but also triggers local outputs precisely when needed. The ZAIO-MI makes it a reality. Whether it’s controlling elevator operations during an alarm, starting a fire pump, or halting ventilation fans, this module’s applications are limitless. It’s the ultimate tool to keep your space safe and secure.

Section 3: Cutting-Edge Features

The ZAIO-MI sets itself apart with a host of cutting-edge features:

  • Loop Powered: Connect up to 60 devices per loop for extensive coverage.
  • User-Friendly Addressing: Choose between an 8-way dip switch or our handheld MKII Programmer (part no. 48-004) for hassle-free addressing.
  • Short Circuit Line Isolator: Enhance reliability and safety with built-in protection.
  • Front Unit Indications: Stay informed with clear status LED indications, including field contact activation, relay energization, input status, device polling, and circuit isolation.

Electrical Data:

  • Model: ZAIO-MI
  • Part Number: 48-108
  • Operating Voltage: 17-28V DC
  • Quiescent Current @ 24V: 1.0mA (20KΩ E.O.L fitted)
  • Switch Input Closed (LED OFF): 1.25mA
  • Relay Operated (LED ON): 2.0mA (Max 2 LEDs on)
  • Minimum Operating Temperature: 0°C
  • Operating Temperature Range: -10°C to +55°C
  • Maximum Humidity: 95% RH (Non-Condensing)
  • IP Rating: IP43
  • Dimensions (mm): 150 x 90 x 45
  • Weight: 220g

Upgrade your fire safety infrastructure with the Fyreye MkII Addressable Input/Output Module (ZAIO-MI) today. Trust in cutting-edge technology to protect what matters most – your safety.

Weight 0.3 kg
Dimensions 1.5 × 0.9 × 0.45 cm

Reviews

There are no reviews yet.

Be the first to review “Zeta Fyreye MkII Addressable Fire Alarm i/o Module With Isolator”

Your email address will not be published. Required fields are marked *

SKU: Zeta Fyreye MkII Addressable Fire Alarm i/o Module With Isolator ZAIO-MI. Categories: , , , , Tags: , , , , , , , ,

You may also like…

  • CONCEPT (Burglar Alarm) PSTN GSM Alarm System with 16 Wireless 16 Wired Zones

    Original price was: ₦96,000.00.Current price is: ₦95,000.00.
    Power supply:                   AC220V+10%
    Stand by consume current:         ≤100mA
    Power:                           <1.5W
    Alarm output current:              <650mA, 12V
    Output voltage:           DC12V~15V
    Wireless receiver frequency:        315MHZ
    Working temperature:              -10 ~55°C
    Working Humidity:                  40 ~70%
    Weight:                           2.5 kegs
    Metal box size             255mm×235mm×70mm
    Keypad size:             159mm×138mm×33mm
    Add to cart
  • Out of Stock

    Apollo (Fire Alarm) AlarmSense Relay Module Part No. 55000-835APO

    Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system. Can also be used to monitor and switch conventional sounders and visual indicators. Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels. Operates in three configurations:- (1) relay activation places the AlarmSense Zone voltage …

    Apollo (Fire Alarm) AlarmSense Relay Module Part No. 55000-835APORead More

    Read more
  • Gent Fire Alarm 4 Channel Interface I/O (PCB Only) S4-34450

    Original price was: ₦250,000.00.Current price is: ₦235,000.00.
    • Loop Powered devices reducing cost of installation and maintenance
    • Individual addresses to maximise information and flexible cause and effect
    • Each device with EN54-17 short circuit handling for enhanced system integrity
    • Comprehensive range of functionality in each device variant to simplify system design
    • Complete range of mounting enclosures and accessories
    • Options to connect conventional fire detectors such as flame and beam detectors
    • Certified to EN54-17 and EN54-18
    Add to cart
  • Out of Stock

    Conventional Sounder Isolator Controller Part No. BF365SC

    • Designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Easily interfaced to a conventional fire alarm sounder circuit.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
    • Fits on standard UK 25mm flush or surface mount back boxes