Zeta Fyreye MkII Addressable Fire Alarm Input Module With Isolator

Original price was: ₦75,000.00.Current price is: ₦73,000.00.

  • Loop-powered (60 devices per loop as maximum)
  • Hand addressed using the 8-way dip switch OR
  • Softly addressed using our handheld MKII
  • Programmer (part no. 48-004)
  • Equipped with short circuit line isolator
  • Extensive front unit indications
Compare

Introducing the Fyreye MkII Addressable Fire Alarm Input Module with Isolator (ZAI-MI) – Your Ultimate Solution for Enhanced Fire Safety Monitoring!

Unlock a new era of fire safety with the ZAI-MI, a cutting-edge input module designed to provide seamless monitoring and alarm capabilities. Engineered to meet the stringent standards of EN54-18 2005 and EN54-17 2005, this module is a game-changer in fire safety technology.

 

Unparalleled Protection:

Incorporated within a modern 2-gang box-sized enclosure, the ZAI-MI fire alarm boasts a state-of-the-art electronic circuit board that offers robust protection during installation. Say goodbye to worries about damage – we’ve got you covered.

Versatile Installation:

The ZAI-MI arrives with a convenient back box, making it ideal for surface-mount indoor installation. Whether you’re safeguarding a commercial space, industrial facility, or residential building, this module is your reliable companion.

Applications Galore:

The ZAI-MI isn’t just another fire safety gadget – it’s a comprehensive solution. Monitor and raise alarms from various ancillary equipment, including sprinkler flow switches, aspiration detectors, secondary fire control panels, beam detectors, external power supplies, and more. With the ZAI-MI, you’re in control of your safety.

Special Features that Impress:

  • Loop powered with support for up to 60 devices per loop, ensuring extensive coverage.
  • Effortlessly address it using the 8-way dip switch or our user-friendly MKII Programmer (part no. 48-004).
  • Equipped with a short circuit line isolator, enhancing reliability and safety.
  • Enjoy clear front unit indications, including alarm, fault, communication status, and isolating alerts.

Electrical Data:

  • Model: ZAI-MI
  • Part Number: 48-101
  • Operating Voltage: 17-28V DC
  • Quiescent Current @ 24V: 1.0mA (20KΩ E.O.L fitted)
  • Switch Input Closed (LED OFF): 1.25mA
  • Switch Input Closed (LED ON): 3.60mA
  • Minimum Operating Temperature: 0°C
  • Operating Temperature Range: -10°C to +55°C
  • Maximum Humidity: 95% RH (Non-Condensing)
  • IP Rating: IP43
  • Dimensions (mm): 150 x 90 x 45
  • Weight: 220g

Front Unit Indications:

  • Alarm: Illuminated red when the Input Module is in alarm.
  • Fault: Illuminated yellow when the Input Module is in fault.
  • Polling: Flashed green when the Input Module is in communication with the panel.
  • Isolating: Illuminated yellow when the loop experiences a short or incorrect connection circuit.

Upgrade your fire safety infrastructure with the Fyreye MkII Addressable Input Module With Isolator (ZAI-MI) today. Trust in cutting-edge technology to protect what matters most – your safety.

Weight 0.3 kg
Dimensions 1.5 × 0.9 × 0.45 cm

Reviews

There are no reviews yet.

Be the first to review “Zeta Fyreye MkII Addressable Fire Alarm Input Module With Isolator”

Your email address will not be published. Required fields are marked *

SKU: Zeta Fyreye MkII Addressable Fire Alarm Input Module With Isolator (ZAI-MI) Categories: , , , , Tag:

You may also like…

  • Gent Fire Alarm Input Interface Module (Supervisory Inputs Only) S4-34412 12

    The S4-32212 module has been designed to be installed in custom panel to provide supervisory input to control plant via Vigilon System. The module connects to a loop circuit of a Vigilon fire alarm control panel.

    Read more
  • Apollo (Fire Alarm) AlarmSense Relay Module Part No. 55000-835APO

    Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system. Can also be used to monitor and switch conventional sounders and visual indicators. Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels. Operates in three configurations:- (1) relay activation places the AlarmSense Zone voltage …

    Apollo (Fire Alarm) AlarmSense Relay Module Part No. 55000-835APORead More

    Read more
  • C-TECH CONVENTIONAL FIRE ALARM CFP 2 Zone Fire Alarm Panel-CFP702-2

    Original price was: ₦119,000.00.Current price is: ₦115,000.00.
    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
    • Manufactured by C-TEC in the UK.
    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
    • Four conventional sounder circuits.
    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
    • Two on-board relays (Fire and Fault).
    • Two open-collector outputs (Remote and Reset).
    • ‘Class change’ and alert inputs.
    • Installer-friendly design.
    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
    • Low 25mA quiescent current.
    • Multiple indicators.
    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
    • Space for two x 12V 3.3Ah VRLA batteries.
    Add to cart
  • Conventional Sounder Isolator Controller Part No. BF365SC

    • Designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Easily interfaced to a conventional fire alarm sounder circuit.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
    • Fits on standard UK 25mm flush or surface mount back boxes