Welcome to Safe Tech Hub

Cart

Your Cart is Empty

Back To Shop

Category: Addressable fire alarm

Showing 177–192 of 244 results

  • INTELLIGENT MANUAL CALL POINT SA5900-908APO

    The Manual Call Point is used to manually initiate an alarm signal on the fire detection system.

    • EN 54-11 & EN 54-17 Certified
    • Resettable operating element
    • 170° viewable LED
    • Suitable for semi flush or surface mounting
    • ‘Plug and Play’ terminal connections for faster wiring
    • Continuity link for wiring test before commissioning
    • XP95, Discovery and CoreProtocol compatible
    Read more
  • KLAXON FLASH GUARD FIRE ALARM SYSTEM-LED BEACONS QBS-0060

    • Compact, ultra-modern sleek appearance
    • Long life Led design
    • Ease of installation with first-fix option on standard models
    • Weatherproof to IP65, up to IP67 with a separate cable connector
    • White, high-quality polycarbonate housing
    • Vandal-resistant safety locking mechanism
    • Flashing or Static Indicators
    • 11-35VDC (Flashing or Static) 240VAC (Flashing Only)
    • Current: 11-35VDC (50mA) 240VAC (32mA)
    • Flash Rate: 1Hz
    • Operating temperatures: -20c – +70c
    • IP Rating: IP65 (Standard) IP67 (with cable connector)
    Read more
  • Manual ‘No Break’ Call Point, surface Part No. BF370MR

    • Certified to EN54 Part 11 (LPCB/VdS).
    • Unique ‘Plug & Play’ installation concept.
    • Supplied with a non-breaking plastic resettable element.
    • Includes a 470Ω resistor, test key and red back box.
    • Anti-Tamper facility.
    • Flush version (without a red back box) also available (order code BF370MFR).
    Read more
  • Manual IP67 ‘Crack Glass’ Call Point, surface Part No. BF370/W

    • Certified to EN54 Part 11 (LPCB/VdS).
    • Weather resistant and sealed to IP67.
    • Ideal for use in external environments where water and dirt are likely to be present.
    • Unique ‘Plug & Play’ installation concept.
    • Supplied with a glass element.
    • Includes a 470Ω resistor and test key.
    • Anti-Tamper facility.
    • Wide -25ºC to +70ºC operating range.
    Read more
  • Message Controller, Fire Alarm System (PNV-0003)

    When combined with a Message controller, voice sounders can transmit upto 7 messages via a simple two-core cable.
    The control unit has two status indication LED’s mounted on its front face; a green ‘System Health’ indicator and an amber ‘fault indicator’

    Read more
  • NDKB1 Carbon Monoxide Detector

    0.00
    • Test button for alarm simulation.
    • Green LED to confirm the unit is under normal operation.
    • Two modes of the Alarm LED in visible and audible warning to easily identify the status.
    • Three modes of the Fault LED in visible and audible warning to easily identify the causes.
    • Triple-color LED display with high brightness enables viewers to easily identify the status of detector.
    • A set of relay output: COM. N.O. N.C. (NDKB1)
    Read more
  • Nexus 105 Sounder Beacon (AC) | Fire Alarm System

    • IP Rating: IP66
    • Operating temperature: -25C – +55C
    • Cable Entries: 5
    • Weight: 0.8kg
    • Applications: Conveyors, process control alarms, cranes, moving machinery, general signalling
    • Available in different colour lenses such as red, amber, clear, blue, green
    Read more
  • Nexus 105 Sounder Beacon (DC) | Fire Alarm System

    • IP Rating: IP66
    • Operating temperature: -25C – +70C
    • Cable Entries: 5
    • Weight: 0.8kg
    • Applications: Conveyors, process control alarms, cranes, moving machinery, general signalling
    • Available in different colour lenses such as red, amber, clear, blue, green
    Read more
  • Nexus 120 Sounder Beacon (AC) Fire Alarm System

    • IP Rating: IP66
    • Operating temperature: -25C – +55C
    • Cable Entries: 5
    • Weight: 2kg
    • Applications: Conveyors, process control alarm, cranes, moving machinery, general signalling
    • Available in different color lens such as red, amber, clear, blue, green
    Read more
  • Nexus 120 Sounder Beacon (DC) Fire Alarm System

    • IP Rating: IP66
    • Operating temperature: -25C – +70C
    • Cable Entries: 5
    • Weight: 2kg
    • Compliance: EN54-3 Type B
    • Applications: Fire alarms, conveyors, process control alarms, cranes, moving machinery, general signalling
    • Available in different color lenses such as red, amber, clear, blue, green
    • its of 2 beacon type: xenon beacon, led beacon
    Read more
  • Nexus Sounder (AC)PNS-0009 | Addressable Fire Alarm System

    This high output sounder is designed for industrial applications. Connections are made to the base during the initial wiring phase which results in faster and more reliable installation. In addition, the head is fixed by quarter-turn fasteners avoiding the need to screw up four individual screws thus enabling faster installation and accurate seal compression for …

    Nexus Sounder (AC)PNS-0009 | Addressable Fire Alarm SystemRead More

    Read more
  • Notifier Honeywell DOM 4-24 Digital Output Fire Alarm Module (583362.22.IPMSG)

    0.00

    The DOM (Digital Output Module) is the central control element of VARIODYN D1. It has interfaces to all input/output assemblies, administers, and monitors the loudspeaker circuits for voice alarm systems and electro-acoustic emergency warning system per EN 60849 and EN 50849. Large or complex system configurations can be implemented through the networking of multiple DOMs via Ethernet. The DOM offers a high level of automatic and constant monitoring as standard. All connected power amplifiers are permanently monitored by the DOM and if a power amplifier becomes faulty, it can be replaced dynamically by a backup amplifier or a backup amplifier channel. The switchover is done automatically by the DOM. The loudspeaker lines are permanently monitored for short circuit, ground fault, and failure as well as impedance deviation. Faulty loudspeaker zones are separated in a non-reacting manner. A DOM contains storage capacity for preset announcements, which can be used for alarm texts and signals (escape alarm, caution signal) and warning signals (gongs). The volume of each source and each amplifier channel can be controlled. Additional filters like parametric equalizer, high-and low pass filter are available.

    Read more
  • Notifier Honeywell VARIODYN D1 Comprio 4-8 Fire Alarm Control Panel with Ethernet (583944.IPMSG)

    0.00

    Comprio is the central control panel of a VARIODYN D1 system for small and medium sized projects. When combined with the 4XD125B or 4XD250B four channel amplifiers, they provide a complete voice alarm system for projects such as schools and small hotels. The emergency power supply is integrated into the 4XD125B and 4XD250B four channel amplifiers.

    Read more
  • Q05 EN Combination Smoke and Heat Detector

    0.00
    • EN54-7 & EN54-5 Approval.
    • The standard detector is 2-wire or 3-wire with base.
    • For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
    • Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
    • Detector is made of high endurance, solid and colorfast Fire-proof plastic.
    • Non-loosening screws on base terminal for easy installation.
    • Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
    Read more
  • Rapid Response Fire Safety: Manual Call Point for Vigilon & Nano Systems | (Excludes Back Box) S4-34842

    • Resettable or break glass
    • Lift up protective covers
    • Up to 200 per loop
    • Integral short-circuit isolator
    Read more
  • Revolutionize Fire Alarm Control with Gent VIG-BNG-RW Bacnet Gateway – Seamless BACnet Integration for Enhanced Safety

    Introducing the Gent VIG-BNG-RW Bacnet Gateway Assembly for Vigilon & Compact with Controls & Command Builds Unlock seamless integration and advanced communication with the BACNET-GW-3, an innovative solution bridging NOTIFIER’s fire panel network and BACnet/IP protocol. This state-of-the-art gateway transforms NFN fire alarm control panels into BACnet objects, ensuring efficient data exchange and enhanced control. …

    Revolutionize Fire Alarm Control with Gent VIG-BNG-RW Bacnet Gateway – Seamless BACnet Integration for Enhanced SafetyRead More

    Read more

Cart

Your Cart is Empty

Back To Shop