Welcome to Top Store

Cart

Your Cart is Empty

Back To Shop

Category: Control Panel

Control panels connect detectors, alarms, suppression systems, and monitoring stations to communicate fire detection and response signals.
Control panel activate visual, audio, and occasionally other forms of notification equipment to alert residents of an emergency situation.

There are two kinds of fire panels available today: Addressable fire alarm panel vs. conventional fire alarm panel. A conventional fire alarm control panel employs one or more circuits, connected to initiating devices wired in parallel. Addressable panels are more advanced than traditional panels, with greater information capacity and control flexibility.

Voice evacuation panels are another type of fire alarm control panel. Designed to provide outputs for speakers in the system.

A fire suppression system will be installed on important and valuable structures. The panel notifies a monitoring center of the alarm status, and people at the receiving location decide what to do next. The panel controls HVAC systems, building automation controls, access points, and elevators to isolate the fire or route workers.

Showing 1–16 of 46 results

  • Sale!

    C-TEC CFP 8 Zone Repeater Panel Part No. CFP760

    Original price was: ₦ 300,000.00.Current price is: ₦ 295,000.00.
      • Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).

      • Up to 8 repeaters per CFP master.

      • Includes its own Mains power supply that requires its own standby battery supply.

      • Provides the user with access to all AL1 and AL2 functions.

      • Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).

      • Communicates over screened two-wire fire resistant cable.

      • Total repeater network cable length should not exceed 1KM.

      • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    Add to cart Buy now
  • Sale!

    C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel

    Original price was: ₦ 200,000.00.Current price is: ₦ 195,000.00.
    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

    Add to cart Buy now
  • Sale!

    C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel

    Original price was: ₦ 250,000.00.Current price is: ₦ 222,000.00.
    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

    Add to cart Buy now
  • Sale!

    C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel

    Original price was: ₦ 300,000.00.Current price is: ₦ 295,000.00.
    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

    Add to cart Buy now
  • Sale!

    C-TEC EP203 Automatic Extinguisher Panel Part No. EP203

    Original price was: ₦ 600,000.00.Current price is: ₦ 570,000.00.
    • Technical Specifications

    • Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.

    • Mains supply 230V 50/60Hz.

    • Mains rated current 810mA max.

    • Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).

    • Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).

    • Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.

    • Max battery size and type 2 x 12V 7Ah VRLA connected in series.

    • No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).

    • Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).

    • No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).

    • EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).

    • Max. sounder output current 3 x 200mA.

    • Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole

      changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via

      EP212 relay card.

      Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to

      be active for 1-300 seconds and to flood for 60-1800 seconds.

      Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;

      1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.

      Indicators Multiple indicators are provided – refer to the EP203 instructions for details.

      Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual

      only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound

      sounders and scrolling.

      Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy

      status units (2 wire power + 2 wire mode select).

      Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).

      Construction & finish Metal back box; metal chassis’ plastic lid.

      IP Rating IP30.

      Weight 4.2kg (without batteries).

      Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%

    Add to cart Buy now
  • Sale! C-Tec FP 8-Zone Fire Alarm Panel

    C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2

    Original price was: ₦ 125,000.00.Current price is: ₦ 120,000.00.

    C-Tec CFP 8 Zone Conventional Fire Alarm Panel Ff388-2   Ff388-2 certified to EN54-2/4, C-TEC’s CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change …

    C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2Read More

    Add to cart Buy now
  • C-TEC IP66 Rated Enclosure for EVC302GF or EVC302F Outstations Part No. BF359/1

      • An attractive IP66 rated enclosure designed for use with a SigTEL EVC302GF or EVC302F flush mounting disabled refuge controller.
      • Includes a handle and mounting plate.
      • Measures 200 W x 302 H x 123mm deep.
      • Textured RAL 7035 (light grey) finish.
      • Also compatible with C-TEC’s EP210F remote status units.
    Read more
  • C-TEC Output Expansion Relay Board Part No. EP212

      • An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
      • Mounts inside the EP203 panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
      • Reset relay switches during the panel’s reset cycle.
      • Mode relay switches when the extinguishant system’s mode is changed to manual.
      • Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
      • Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
      • Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
    Read more
  • C-TEC Remote Status Unit, Surface Part No. EP210S

          • DESCRIPTION
          • Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
          • Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
          • Three monitored input connections (Hold, Abort and Mode).
          • Max. 8 remote status units per EP203 panel.
          • Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
    Read more
  • C-TEC System Line Terminator Part No. EP214

          • An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
          • Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
          • One EP214 terminator is required per solenoid.
          • Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
          • Measures just 55m W x 55mm H x 22mm D.
    Read more
  • Fire Alarm Control Panel Mains Keyswitch Part No. BF319

    • A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
    • Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
    • Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
    • Fits on a standard UK 47mm flush or surface mount back box.
    • Supplied with 2 x M3.5 25mm fixing screws.
    • BS EN60669-1 compliant.
    • Always read the full installation and operating instructions supplied with the unit before use.
    Read more
  • Sale! Gent 4-ZONE CONVENTIONAL PANEL

    Gent 4 ZONE CONVENTIONAL PANEL

    Original price was: ₦ 720,000.00.Current price is: ₦ 708,750.00.

    DESCRIPTION

    Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

    BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.

    Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.

    Add to cart Buy now
  • Sale! White and blackGent 8-ZONE REPEAT INDICATOR

    GENT 8 ZONE REPEAT INDICATOR, LESS BATTERIES (13271-08LB)

    Original price was: ₦ 265,000.00.Current price is: ₦ 255,000.00.

    Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 (Less Batteries)

    BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.

    Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.

    Utilising LPCB approved conventional smoke or heat detectors, Xenex offers exceptional value for money.

    Add to cart Buy now
  • Gent BACnet Gateway Assembly

    Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds (VIG-BNG-RW)

     825,000.00

    Gent BACnet Gateway Assembly for Vigilon Plus & Compact Plus with Controls & Command Builds

    The BACnet protocol is a Standard (Ansi/Ashrae 135-2004). With the Gent BACnet Gateway Assembly, devices on Vigilon fire alarm control panels are represented as BACnet objects to the BACnet client. The user subscribes to Event Notification objects from the FACP as required and the BACnet device receives events from objects on the FACP as a result of the subscription.

    Add to cart Buy now
  • Sale!

    Gent C3-SN-R Electronic 2way Sounder Red

    Original price was: ₦ 15,500.00.Current price is: ₦ 12,000.00.

    Low profile GENT sounder, ideal for use in environments where aesthetics should be discrete as possible. The GENT S3-SN-R Electronic 2 way Sounder Red is rated at 100 dBA but can be remotely configured using the HandiLink IR remote control to turn on individual sounders when in commissioning mode and to adjust the volume. Access is no …

    Gent C3-SN-R Electronic 2way Sounder RedRead More

    Add to cart Buy now
  • Gent C3-SN-W Electronic 2way Sounder White

     19,000.00

    Low profile GENT sounder, ideal for use in environments where aesthetics should be discrete as possible. The GENT S3-SN-R Electronic 2 way Sounder White is rated at 100 dBA but can be remotely configured using the HandiLink IR remote control to turn on individual sounders when in commissioning mode and to adjust the volume. Access …

    Gent C3-SN-W Electronic 2way Sounder WhiteRead More

    Add to cart Buy now
Select your currency
NGN Nigerian naira
Shopping cart0
There are no products in the cart!
Continue shopping
0

Cart

Your Cart is Empty

Back To Shop