Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Cable
- Call Point
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
Zeta BreakGlass Yellow
₦ 32,000.00Original price was: ₦ 32,000.00.₦ 31,500.00Current price is: ₦ 31,500.00. -
Zeta Weatherproof Fire Alarm Breakglass Red
₦ 29,000.00Original price was: ₦ 29,000.00.₦ 28,875.00Current price is: ₦ 28,875.00. -
Gent Four-Channel Mains Switching Interface with Enclosure (S4-3440-02)
₦ 1,900,000.00Original price was: ₦ 1,900,000.00.₦ 1,890,000.00Current price is: ₦ 1,890,000.00. -
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 125,000.00Original price was: ₦ 125,000.00.₦ 120,000.00Current price is: ₦ 120,000.00. -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦ 15,000.00Original price was: ₦ 15,000.00.₦ 13,000.00Current price is: ₦ 13,000.00.
Tag Clouds
Category: Conventional Fire Alarm System
Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
Showing 1–16 of 202 results
-
AlarmSense Optical Smoke Detector
₦ 25,000.00Original price was: ₦ 25,000.00.₦ 23,000.00Current price is: ₦ 23,000.00.Add to cart Buy nowAlarmSense Optical Smoke Detector – Reliable Fire Safety by Trends Ventures Limited
Stay protected with the AlarmSense Optical Smoke Detector, built for fast, accurate smoke detection. Perfect for homes, offices, and commercial buildings, it integrates easily into AlarmSense two-wire systems for efficient installation.
Key Features:
-
Fast response to slow-burning fires
-
Reduced false alarms
-
Compatible with AlarmSense control panels
-
Easy installation & low maintenance
-
LED status indicator for clear alerts
Now available at Trends Ventures Limited – your trusted fire and safety partner.
-
-
AlarmSense Standard Rate of Rise Heat Detector
₦ 24,000.00Original price was: ₦ 24,000.00.₦ 22,000.00Current price is: ₦ 22,000.00.Add to cart Buy nowWhen every second counts, trust the technology that responds fast and reliably. The AlarmSense Standard Rate of Rise Heat Detector is designed to detect rapid temperature increases, providing early warning of fire without false alarms triggered by daily heat variations.
Perfect for residential, commercial, and industrial applications, this intelligent device works seamlessly with AlarmSense two-wire systems—offering an efficient and cost-effective fire safety solution.
✅ Rapid Heat Detection
✅ Highly Accurate and Reliable
✅ Easy Installation with Two-Wire Technology
✅ Ideal for Kitchens, Warehouses, and Utility SpacesAt Trends Ventures Limited, your safety is our priority. Equip your buildings with advanced fire detection technology today and ensure peace of mind for tomorrow.
-
APOLLO AlarmSense Open Area Sounder IP65
₦ 100,000.00Original price was: ₦ 100,000.00.₦ 99,000.00Current price is: ₦ 99,000.00.Add to cart Buy now-
A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
-
IP65 rated.
-
Up to 99dB(A) sound output at 1m.
-
Ultra-bright red LED.
-
Device locking facility.
-
Max. five Open-Area Alarm Devices per AlarmSense zone.
-
-
APOLLO XP95 OPTICAL SMOKE DETECTOR 55000-620APO
₦ 25,500.00Original price was: ₦ 25,500.00.₦ 24,500.00Current price is: ₦ 24,500.00.Add to cart Buy nowThe XP95 Optical Smoke Detector uses the light scatter principle to quickly and effectively detect a range of slow burning and smouldering fires.
- Reliable fire detection in areas with a wide temperature range from -20°C to +60°C
- Ideal for escape routes
- Unaffected by wind and atmospheric pressure
- Insect resistant screen
-
C-TEC ActiV Optical Smoke Detector Part No. C4416
₦ 30,000.00Original price was: ₦ 30,000.00.₦ 28,000.00Current price is: ₦ 28,000.00.Add to cart Buy now-
-
-
DESCRIPTION
-
A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.
-
Manufactured by C-TEC in the UK.
-
Third-party certified to EN54-5 by Intertek.
-
Wide 6-33V DC operating voltage.
-
Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
-
Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.
-
-
-
-
C-TEC CFP 8 Zone Repeater Panel Part No. CFP760
₦ 300,000.00Original price was: ₦ 300,000.00.₦ 295,000.00Current price is: ₦ 295,000.00.Add to cart Buy now-
-
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
-
Up to 8 repeaters per CFP master.
-
Includes its own Mains power supply that requires its own standby battery supply.
-
Provides the user with access to all AL1 and AL2 functions.
-
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
-
Communicates over screened two-wire fire resistant cable.
-
Total repeater network cable length should not exceed 1KM.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
-
-
C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel
₦ 200,000.00Original price was: ₦ 200,000.00.₦ 195,000.00Current price is: ₦ 195,000.00.Add to cart Buy now-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
-
-
C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel
₦ 250,000.00Original price was: ₦ 250,000.00.₦ 222,000.00Current price is: ₦ 222,000.00.Add to cart Buy now-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
-
-
C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel
₦ 300,000.00Original price was: ₦ 300,000.00.₦ 295,000.00Current price is: ₦ 295,000.00.Add to cart Buy now-
Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).
-
Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
-
Manufactured by C-TEC in the UK.
-
Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.
-
Four conventional sounder circuits.
-
Integral 1.5A EN54-4/A2 compliant switch mode PSU.
-
Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
-
Two on-board relays (Fire and Fault).
-
Two open-collector outputs (Remote and Reset).
-
‘Class change’ and alert inputs.
-
Installer-friendly design.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
Low 25mA quiescent current.
-
Multiple indicators.
-
System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).
-
Space for two x 12V 3.3Ah VRLA batteries.
-
-
C-TEC Economy Status Unit Part No. EP211
₦ 159,000.00Original price was: ₦ 159,000.00.₦ 156,000.00Current price is: ₦ 156,000.00.Add to cart Buy now-
-
-
Designed to connect to the EP203 Automatic Extinguisher Panel to provide remote system status indication via three LEDs.
-
Includes a mode (auto/manual) keyswitch.
-
Mounts on a standard UK single gang 25mm flush or surface back box.
-
Max. 8 economy status units per EP203 panel.
-
-
-
-
C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
₦ 600,000.00Original price was: ₦ 600,000.00.₦ 570,000.00Current price is: ₦ 570,000.00.Add to cart Buy now-
Technical Specifications
-
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
-
Mains supply 230V 50/60Hz.
-
Mains rated current 810mA max.
-
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
-
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
-
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
-
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
-
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
-
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
-
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
-
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
-
Max. sounder output current 3 x 200mA.
-
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
-
-
C-TEC Flushing Mount Remote Status Unit Part No. EP210F
₦ 320,000.00Original price was: ₦ 320,000.00.₦ 300,000.00Current price is: ₦ 300,000.00.Add to cart Buy now-
-
-
-
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
-
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
-
Three monitored input connections (Hold, Abort and Mode).
-
Max. 8 remote status units per EP203 panel.
-
Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
-
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 125,000.00Original price was: ₦ 125,000.00.₦ 120,000.00Current price is: ₦ 120,000.00.Add to cart Buy nowC-Tec CFP 8 Zone Conventional Fire Alarm Panel Ff388-2 Ff388-2 certified to EN54-2/4, C-TEC’s CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change …
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2Read More
-
C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3
₦ 120,000.00Add to cart Buy now-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Eight conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
C-TEC Manual ‘Crack Glass’ Call Point, surface Part No. BF370R
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
C-TEC Manual ‘Crack Glass/No Break’ Call Point, flush/surface Part No. BF370FR
Read more- Certified to EN54 Parts 11 (LPCB) and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More